EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Opportunistic Screening for Low Bone Density Using Automated Vertebral Trabecular CT Attenuation from Low-Dose CT Acquired During FDG PET/CT: A Single-Center Retrospective Study

Hyun-Kyeong Yuk iD, Sung-Hoon Oh iD, Do-Hoon Kim iD

Tomography · 17.06.2026 · 12 (6) · 89

DOI: 10.3390/tomography12060089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, online erschienen am 17.06.2026. Verfasst von Hyun-Kyeong Yuk und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Daejeon Eulji Medical Center, Daejeon 35233, Republic of Korea. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Bone Density, Lumbar Vertebrae, Cancellous Bone. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the diagnostic performance of automated vertebral trabecular Hounsfield unit (HU) measurements derived from routine fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) for identifying low bone density.

Methods

This retrospective study included 131 consecutive women (mean age, 53.5 ± 9.6 years) undergoing health screening with FDG PET/CT and dual-energy X-ray absorptiometry (DXA) between January 2020 and December 2024. A deep learning-based model (TotalSegmentator) automatically segmented the lumbar vertebrae (L1–L4). HU-based metrics in trabecular regions were calculated, and their correlations with DXA-derived bone mineral density (BMD) were assessed. Diagnostic performance was evaluated using receiver operating characteristic analysis. A multivariable logistic regression model incorporating mean HU, age, and body mass index was developed and internally validated using bootstrap resampling.

Results

According to WHO criteria, 47 of 131 participants (35.9%) had low bone density. Mean HU demonstrated strong diagnostic performance (area under the curve [95% confidence interval]: L1, 0.861 [0.800–0.923]; L2, 0.852 [0.788–0.915]; L3, 0.861 [0.800–0.921]; L4, 0.845 [0.781–0.909]). L1 mean HU provided the most balanced performance (sensitivity, 0.851; specificity, 0.750); L3 mean HU was slightly inferior. L1 mean HU was strongly correlated with BMD (r = 0.821, p < 0.001). In multivariable analysis, mean HU independently predicted low bone density (odds ratio: 0.949, p < 0.001). The model achieved an accuracy of 0.786 and demonstrated favorable calibration performance.

Conclusions

The automated assessment of vertebral trabecular HU from routine FDG PET/CT provides a reliable and highly efficient method for screening low bone density without additional radiation exposure or cost.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Positron Emission Tomography Computed TomographyBone DensityLumbar VertebraeCancellous BoneOsteoporosisHumansFemaleRetrospective StudiesMiddle AgedFluorodeoxyglucose F18Absorptiometry, PhotonRadiopharmaceuticalsDeep LearningMass Screening

Stichwörter der Autor:innen

automated segmentationbone mineral densitydeep learningopportunistic screeningpositron emission tomography/computed tomography

Substanzen

Fluorodeoxyglucose F18Radiopharmaceuticals

Autor:innen und Institutionen

  • Department of Radiology, Daejeon Eulji Medical Center, Daejeon 35233, Republic of Korea.
  • Department of Nuclear Medicine, Daejeon Eulji Medical Center, Eulji University School of Medicine, Daejeon 35233, Republic of Korea.

ORCID-Profile: Hyun-Kyeong Yuk, Sung-Hoon Oh, Do-Hoon Kim

Zitieren

APA

Yuk, H. K., Oh, S. H., & Kim, D. H. (2026). Opportunistic Screening for Low Bone Density Using Automated Vertebral Trabecular CT Attenuation from Low-Dose CT Acquired During FDG PET/CT: A Single-Center Retrospective Study. Tomography, 12(6), 89. https://doi.org/10.3390/tomography12060089

Vancouver

Yuk HK, Oh SH, Kim DH. Opportunistic Screening for Low Bone Density Using Automated Vertebral Trabecular CT Attenuation from Low-Dose CT Acquired During FDG PET/CT: A Single-Center Retrospective Study. Tomography. 2026;12(6):89. doi:10.3390/tomography12060089

BibTeX
@article{Yuk2026,
  author = {Yuk, Hyun-Kyeong and Oh, Sung-Hoon and Kim, Do-Hoon},
  title = {Opportunistic Screening for Low Bone Density Using Automated Vertebral Trabecular CT Attenuation from Low-Dose CT Acquired During FDG PET/CT: A Single-Center Retrospective Study},
  journal = {Tomography},
  year = {2026},
  volume = {12},
  number = {6},
  pages = {89},
  doi = {10.3390/tomography12060089}
}
Kostenlos starten →