EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Axial X-Ray Microscopy in Nanotomography

Konstantin P Gaikovich iD, Ilya V Malyshev iD, Dmitry G Reunov iD, Nikolay I Chkhalo iD

Tomography · 18.03.2026 · 12 (3) · 41

DOI: 10.3390/tomography12030041 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, online erschienen am 18.03.2026. Verfasst von Konstantin P Gaikovich und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Physics of Microstructures, Russian Academy of Sciences, 603950 Nizhny Novgorod, Russia. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Microscopy. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: This article develops theory and methods for 3D tomographic imaging of absorption coefficient distributions using axial scanning with EUV microscopes at 46× and 345× magnification. Unlike conventional CT that requires sample rotation, axial scanning moves cells through the microscope focus. The aim is tomographic reconstruction of living cell fine structure without the organelle staining used in optical fluorescence microscopy or ultra-thin cell slicing as in electron microscopy.

Methods

By generalizing the geometric-optical approximation for small absorption coefficient inhomogeneities in absorbing media, we derived a new explicit tomography equation and solution algorithm validated through numerical simulation. The approach was applied to Convallaria cell analysis using the ×46 microscope. For the ×345 microscope, we developed an alternative method where the kernel of the tomography integral equation was determined experimentally using gold nanospheres with known absorption coefficient, shape, and position. This method was tested through modeling and applied to diagnostics of Convallaria and mouse cerebellar granule cells.

Results

The developed methods resolve subcellular features down to 140 nm using the ×46 microscope and 50 nm using the ×345 microscope. Thin low-contrast intracellular structures and individual 50–100 nm organelles were detected.

Conclusions

Methods for retrieving absorption coefficient distributions in cone-beam geometry based on geometric-optical theory generalization and on calibration by gold nanoparticles have been developed and validated through numerical simulation and cell analysis. These methods demonstrate for the first time the effectiveness of axial nanotomography using multilayer mirror microscopes for cell diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMicroscopyAnimalsMiceAlgorithmsGold

Stichwörter der Autor:innen

EUV microscopyabsorption coefficientcell tomographynumerical simulationsoft X-ray microscopytomography

Substanzen

Gold

Autor:innen und Institutionen

  • Institute for Physics of Microstructures, Russian Academy of Sciences, 603950 Nizhny Novgorod, Russia.

ORCID-Profile: Konstantin P Gaikovich, Ilya V Malyshev, Dmitry G Reunov, Nikolay I Chkhalo

Förderung

  • Russian Science Foundation

Zitieren

APA

Gaikovich, K. P., Malyshev, I. V., Reunov, D. G., & Chkhalo, N. I. (2026). Axial X-Ray Microscopy in Nanotomography. Tomography, 12(3), 41. https://doi.org/10.3390/tomography12030041

Vancouver

Gaikovich KP, Malyshev IV, Reunov DG, Chkhalo NI. Axial X-Ray Microscopy in Nanotomography. Tomography. 2026;12(3):41. doi:10.3390/tomography12030041

BibTeX
@article{Gaikovich2026,
  author = {Gaikovich, Konstantin P and Malyshev, Ilya V and Reunov, Dmitry G and Chkhalo, Nikolay I},
  title = {Axial X-Ray Microscopy in Nanotomography},
  journal = {Tomography},
  year = {2026},
  volume = {12},
  number = {3},
  pages = {41},
  doi = {10.3390/tomography12030041}
}
Kostenlos starten →