EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Correlation Between Radiological Features of Axillary Lymph Nodes with CD4 Count and Plasma Viral Load in Patients with HIV

Gulten Taskin iD, Muzaffer Elmali iD, Aydin Deveci iD, Irem Ceren Koc iD

Tomography · 25.12.2025 · 12 (1) · 3

DOI: 10.3390/tomography12010003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, online erschienen am 25.12.2025. Verfasst von Gulten Taskin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Faculty of Medicine, Ondokuz Mayıs University, 55270 Samsun, Turkey. Hauptthemen laut MEDLINE: Lymph Nodes, CD4 Lymphocyte Count, Viral Load. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Axillary lymph node changes are frequently observed in patients with HIV, yet their radiological characteristics and clinical significance remain underexplored. This study aimed to evaluate the association between axillary lymph node computed tomography (CT) features and clinical markers of immune function, including CD4 lymphocyte count and plasma viral load, in HIV-positive patients. Materials and Methods: In this retrospective study, 113 HIV-positive patients who underwent contrast-enhanced chest CT were included. Patients were stratified by CD4 count (500 cells/μL) and plasma viral load (100,000 copies/mL). Axillary lymph node parameters—including maximum and minimum diameters, cortical thickness, hilar width, and density (Hounsfield units, HU)—were measured on multiplanar reconstructed CT images. Group differences were assessed using the Kruskal–Wallis and Mann–Whitney U tests, and Spearman’s correlation was used to evaluate associations between imaging and laboratory findings. Receiver operating characteristic (ROC) curve analysis identified optimal density thresholds.

Results

Lymph node diameters, cortical thickness, and hilar width did not significantly differ between CD4 groups. However, mean lymph node density was higher in patients with CD4 < 200 cells/μL (p = 0.024). A density threshold of 84.5 HU distinguished impaired from preserved immune function (sensitivity 61.1%, specificity 71.2%). Patients with viral load >100,000 copies/mL showed increased lymph node density, minimal diameter, and cortical thickness.

Conclusions

Elevated axillary lymph node density correlates with immune suppression and high viral load, suggesting its potential as a non-invasive prognostic imaging biomarker in HIV infection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lymph NodesCD4 Lymphocyte CountViral LoadTomography, X-Ray ComputedAxillaHIV InfectionsHumansMaleFemaleAdultMiddle AgedRetrospective Studies

Stichwörter der Autor:innen

Axillary lymph nodesCD4 lymphocyte countHIV infectionscomputed tomographyviral load

Autor:innen und Institutionen

  • Department of Radiology, Faculty of Medicine, Ondokuz Mayıs University, 55270 Samsun, Turkey.
  • Department of Infectious Diseases and Clinical Microbiology, Faculty of Medicine, Ondokuz Mayıs University, 55270 Samsun, Turkey.

ORCID-Profile: Gulten Taskin, Muzaffer Elmali, Aydin Deveci, Irem Ceren Koc

Zitieren

APA

Taskin, G., Elmali, M., Deveci, A., & Koc, I. C. (2025). Correlation Between Radiological Features of Axillary Lymph Nodes with CD4 Count and Plasma Viral Load in Patients with HIV. Tomography, 12(1), 3. https://doi.org/10.3390/tomography12010003

Vancouver

Taskin G, Elmali M, Deveci A, Koc IC. Correlation Between Radiological Features of Axillary Lymph Nodes with CD4 Count and Plasma Viral Load in Patients with HIV. Tomography. 2025;12(1):3. doi:10.3390/tomography12010003

BibTeX
@article{Taskin2025,
  author = {Taskin, Gulten and Elmali, Muzaffer and Deveci, Aydin and Koc, Irem Ceren},
  title = {Correlation Between Radiological Features of Axillary Lymph Nodes with CD4 Count and Plasma Viral Load in Patients with HIV},
  journal = {Tomography},
  year = {2025},
  volume = {12},
  number = {1},
  pages = {3},
  doi = {10.3390/tomography12010003}
}
Kostenlos starten →