EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Volume and Attenuation Characteristics of Chronic Subdural Hematoma: An Annotated Patient Cohort of 257 Patients with Interrater Reliability Assessments

Mattias Drake iD, Emma Hall iD, Birgitta Ramgren iD, Björn M Hansen iD, Johan Wassélius iD

Tomography · 2025

DOI: 10.3390/tomography11120141 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, 2025. Verfasst von Mattias Drake und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Skåne University Hospital, 22185 Lund, Sweden. Hauptthemen laut MEDLINE: Hematoma, Subdural, Chronic, Tomography, X-Ray Computed. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Region Skåne, Skåne University Hospital, Region Skane.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate volumetry and imaging characterization of chronic subdural hematoma (cSDH) are essential for prognostication and treatment planning, but manual assessment is time-consuming and therefore underutilized.

Methods

We retrospectively analyzed preoperative non-contrast CT (NCCT) scans of 257 patients undergoing first-time surgery for uni- or bilateral cSDH. Hematoma volumes were measured manually using a semi-automated area-outlining tool on every second axial slice and compared with the volumes estimated through the ABC/2 formula. Hematoma attenuation patterns and components were categorized, and interrater reliability was assessed for volume, maximum diameter, and imaging features using intraclass correlation coefficients (ICCs) and Cohen’s κ.

Results

A total of 339 hematomas were evaluated. Manual and ABC/2 volume measurements correlated strongly (R2 = 0.83, ICC [3, 1] = 0.90). The interrater agreement for manual volumetry was excellent (ICC [2, 1] = 0.96). Agreement was also excellent for maximum diameter (ICC [2, 1] > 0.9) and good for midline shift assessment (κ = 0.81). Agreement was moderate for the identification of fresh clots, trabeculations, and laminations (κ = 0.62–0.72) but poor for general attenuation patterns (κ = 0.44).

Conclusions

The manual volumetry of cSDH is feasible and highly reproducible between raters of different experience levels. These results provide a robust reference standard for the validation of automated volumetry tools and support the implementation of quantitative hematoma assessment in future clinical trials and routine care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hematoma, Subdural, ChronicTomography, X-Ray ComputedHumansRetrospective StudiesMaleFemaleReproducibility of ResultsAgedMiddle AgedObserver VariationAged, 80 and overAdult

Stichwörter der Autor:innen

chronic subdural hematomaimagingvolumetry

Autor:innen und Institutionen

  • Department of Radiology, Skåne University Hospital, 22185 Lund, Sweden.
  • Stroke Imaging Research Group, Clinical Sciences Lund (IKVL), Lund University, 22185 Lund, Sweden.

ORCID-Profile: Mattias Drake, Emma Hall, Birgitta Ramgren, Björn M Hansen, Johan Wassélius

Förderung

  • Region Skåne
  • Skåne University Hospital
  • Region Skane
  • Skane University hospital funds

Zitieren

APA

Drake, M., Hall, E., Ramgren, B., Hansen, B. M., & Wassélius, J. (2025). Volume and Attenuation Characteristics of Chronic Subdural Hematoma: An Annotated Patient Cohort of 257 Patients with Interrater Reliability Assessments. Tomography. https://doi.org/10.3390/tomography11120141

Vancouver

Drake M, Hall E, Ramgren B, Hansen BM, Wassélius J. Volume and Attenuation Characteristics of Chronic Subdural Hematoma: An Annotated Patient Cohort of 257 Patients with Interrater Reliability Assessments. Tomography. 2025. doi:10.3390/tomography11120141

BibTeX
@article{Drake2025,
  author = {Drake, Mattias and Hall, Emma and Ramgren, Birgitta and Hansen, Björn M and Wassélius, Johan},
  title = {Volume and Attenuation Characteristics of Chronic Subdural Hematoma: An Annotated Patient Cohort of 257 Patients with Interrater Reliability Assessments},
  journal = {Tomography},
  year = {2025},
  doi = {10.3390/tomography11120141}
}
Kostenlos starten →