Reducing Radiation Dose in Computed Tomography Imaging of Adolescent Idiopathic Scoliosis Using Spectral Shaping Technique with Tin Filter
Tomography · 2025
DOI: 10.3390/tomography11100110 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, 2025. Verfasst von Yoshiyuki Noto und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiological Technology, Department of Technical Support, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan. Hauptthemen laut MEDLINE: Scoliosis, Radiation Dosage, Tomography, X-Ray Computed. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NRA Human Resource Development, Human Resource Development Program for Advanced Radiation Protection with Practical Problem-Solving Skills, Japan..
Abstract (Originalsprache)
Background/Objectives: Children with adolescent idiopathic scoliosis (AIS) require repeated imaging, primarily standing spine radiography, while CT may be required for surgical planning, resulting in higher radiation exposure. Spectral shaping using a tin filter can reduce radiation dose in non-contrast chest CT. This study evaluated the efficacy of spectral shaping using a tin filter for reducing radiation dose in CT imaging in AIS and its impact on image quality.
Methods
We retrospectively analyzed 51 AIS patients who underwent spine CT between February 2017 and March 2022, and divided them into two groups: normal-dose CT (NDCT) and low-dose CT with spectral shaping with a tin filter (LDCT). Radiation doses and image quality were compared between the groups. Radiation dose was recorded as the volume CT dose index (CTDIvol) and the dose length product emitted from the device, and effective and equivalent doses obtained from simulations.
Results
The use of spectral shaping with a tin filter resulted in a 75% reduction in radiation dose compared to conventional CT without any reduction in image quality.
Conclusions
Spectral shaping CT with a tin filter can substantially reduce radiation dose while maintaining image quality. It may be considered a safer alternative to conventional CT when clinically indicated in AIS patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Radiological Technology, Department of Technical Support, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan.
- Course of Radiological Technology, Health Sciences, Tohoku University Graduate School of Medicine, Sendai 980-8575, Japan.
- Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Sciences, Chuo Ward, Niigata 951-8520, Japan.
- Department of Radiation Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, Sendai 980-0845, Japan.
ORCID-Profile: Yoshiyuki Noto, Tatsuya Kuramoto, Kei Watanabe, Koichi Chida
Förderung
- NRA Human Resource Development, Human Resource Development Program for Advanced Radiation Protection with Practical Problem-Solving Skills, Japan.
Zitieren
APA
Noto, Y., Kuramoto, T., Watanabe, K., & Chida, K. (2025). Reducing Radiation Dose in Computed Tomography Imaging of Adolescent Idiopathic Scoliosis Using Spectral Shaping Technique with Tin Filter. Tomography. https://doi.org/10.3390/tomography11100110
Vancouver
Noto Y, Kuramoto T, Watanabe K, Chida K. Reducing Radiation Dose in Computed Tomography Imaging of Adolescent Idiopathic Scoliosis Using Spectral Shaping Technique with Tin Filter. Tomography. 2025. doi:10.3390/tomography11100110
BibTeX
@article{Noto2025,
author = {Noto, Yoshiyuki and Kuramoto, Tatsuya and Watanabe, Kei and Chida, Koichi},
title = {Reducing Radiation Dose in Computed Tomography Imaging of Adolescent Idiopathic Scoliosis Using Spectral Shaping Technique with Tin Filter},
journal = {Tomography},
year = {2025},
doi = {10.3390/tomography11100110}
}
EUVIMED