AI-CAD-Guided Mammographic Assessment of Tumor Size and T Stage: Concordance with MRI for Clinical Staging in Breast Cancer Patients Considered for NAC

Ga Eun Park, Kabsoo Shin iD, Han Song Mun iD, Bong Joo Kang iD

Tomography · 2025

DOI: 10.3390/tomography11070072 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, 2025. Verfasst von Ga Eun Park und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea. Hauptthemen laut MEDLINE: Breast Neoplasms, Magnetic Resonance Imaging, Mammography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the agreement between AI-CAD-guided mammographic and MRI measurements of tumor size and T stage in breast cancer patients being considered for neoadjuvant chemotherapy (NAC).

Methods

This retrospective study included 144 women (mean age, 52 ± 11 years) with invasive breast cancer who subsequently received NAC and underwent both AI-CAD mammography (score ≥ 10) and pre-treatment MRI. Tumor sizes from AI-CAD contours were compared with MRI using Pearson correlation, intraclass correlation coefficients (ICCs), and Bland–Altman analysis. Concordance was defined as a ±0.5 cm difference. The contour showing the highest agreement was used to compare T stage with MRI using weighted kappa.

Results

The mean AI-CAD abnormality score was 86.3 ± 22.2. Tumor sizes on mammography were 3.0 ± 1.2 cm (inner), 3.8 ± 1.5 cm (middle), and 4.8 ± 2.2 cm (outer), while the MRI-measured tumor size was 4.0 ± 1.9 cm. The middle contour showed the strongest correlation with MRI (r = 0.897; ICC = 0.866), the smallest mean difference (–0.19 cm; limits of agreement, –1.87 to 1.49), and the highest concordance (61.1%). Agreement was higher in mass-only lesions than in NME-involved lesions (ICC = 0.883 vs. 0.775; concordance, 70.9% vs. 46.6%). T stage comparison using the middle contour showed substantial agreement with MRI (κ = 0.743 [95% CI, 0.634–0.852]; agreement, 88.2%), with higher concordance in mass-only lesions (93.0%) than NME-involved lesions (81.0%) and more frequent understaging in the latter (17.2% vs. 2.3%).

Conclusions

AI-CAD-guided mammographic assessment using the middle contour demonstrated good agreement with MRI for tumor size and T stage, indicating its value as a supportive tool for clinical staging in MRI-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsMagnetic Resonance ImagingMammographyHumansFemaleMiddle AgedRetrospective StudiesNeoplasm StagingAdultNeoadjuvant TherapyAgedBreastTumor Burden

Stichwörter der Autor:innen

artificial intelligencebreast neoplasmsmammographyneoadjuvant therapyneoplasm staging

Autor:innen und Institutionen

  • Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
  • Division of Medical Oncology, Department of Internal Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.

ORCID-Profile: Kabsoo Shin, Han Song Mun, Bong Joo Kang

Zitieren

APA

Park, G. E., Shin, K., Mun, H. S., & Kang, B. J. (2025). AI-CAD-Guided Mammographic Assessment of Tumor Size and T Stage: Concordance with MRI for Clinical Staging in Breast Cancer Patients Considered for NAC. Tomography. https://doi.org/10.3390/tomography11070072

Vancouver

Park GE, Shin K, Mun HS, Kang BJ. AI-CAD-Guided Mammographic Assessment of Tumor Size and T Stage: Concordance with MRI for Clinical Staging in Breast Cancer Patients Considered for NAC. Tomography. 2025. doi:10.3390/tomography11070072

BibTeX
@article{Park2025,
  author = {Park, Ga Eun and Shin, Kabsoo and Mun, Han Song and Kang, Bong Joo},
  title = {AI-CAD-Guided Mammographic Assessment of Tumor Size and T Stage: Concordance with MRI for Clinical Staging in Breast Cancer Patients Considered for NAC},
  journal = {Tomography},
  year = {2025},
  doi = {10.3390/tomography11070072}
}
Kostenlos starten →