Four-Dimensional Dual-Energy Computed Tomography-Derived Parameters and Their Correlation with Thyroid Gland Functional Status

Max H M C Scheepers, Zaid J J Al-Difaie, Nicole D Bouvy, Bas Havekes, Alida A Postma

Tomography · 2025

DOI: 10.3390/tomography11030022 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, 2025. Verfasst von Max H M C Scheepers und 4 weiteren Autor:innen. Beteiligte Einrichtung: GROW Research Institute for Oncology and Reproduction, Maastricht University, 6229 ER Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Thyroid Gland, Four-Dimensional Computed Tomography, Radiography, Dual-Energy Scanned Projection, Hyperparathyroidism, Primary. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the institutional grants Siemens healthineers, Bayer healthcare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Dual-energy computed tomography (DECT) allows for the measurement of iodine concentration, a component for the synthesis of thyroid hormones. DECT can create virtual non-contrast (VNC) images, potentially reducing radiation exposure. This study explores the correlations between thyroid function and iodine concentration, as well as the relationship between thyroid densities in true non-contrast (TNC) and virtual non-contrast (VNC) images and thyroid function.

Methods

The study involved 87 patients undergoing 4D-CT imaging with single and dual-energy scans for diagnosing primary hyperparathyroidism. Thyroid densities and iodine concentrations were measured across all scanning phases. These measurements were correlated with thyroid function, indicated by TSH and FT4 levels. Differences in thyroid density between post-contrast phases and TNC phases (ΔHU) were analyzed for correlations with thyroid function and iodine concentrations.

Results

Positive correlations between iodine concentrations and TSH were found, with Spearman’s coefficients (R) of 0.414, 0.361, and 0.349 for non-contrast, arterial, and venous phases, respectively. Thyroid density on TNC showed significant positive correlations with TSH levels (R = 0.436), consistently across both single- (R = 0.435) and dual-energy (R = 0.422) scans. Thyroid densities on VNC images did not correlate with TSH or FT4. Differences in density between contrast and non-contrast scans (ΔHU) negatively correlated with TSH (p = 0.002).

Conclusions

DECT-derived iodine concentrations and thyroid densities in non-contrast CT scans demonstrated positive correlations with thyroid function, in contrast to thyroid densities on VNC scans. This indicates that VNC images are unsuitable for this purpose. Correlations between ΔHU and TSH suggest a potential link between the thyroid’s structural properties to capture iodine and its hormonal function. This study underscores the potential value of (DE-) CT imaging for evaluating thyroid function as an additional benefit in head and neck scans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thyroid GlandFour-Dimensional Computed TomographyRadiography, Dual-Energy Scanned ProjectionHyperparathyroidism, PrimaryHumansMaleFemaleMiddle AgedAgedAdultIodineThyroid Function TestsThyrotropinAged, 80 and over

Stichwörter der Autor:innen

computed tomography (CT)dual-energy CT (DECT)four-dimensional CT (4D-CT)head and neck imagingiodine concentrationthyroid function

Substanzen

IodineThyrotropin

Autor:innen und Institutionen

  • GROW Research Institute for Oncology and Reproduction, Maastricht University, 6229 ER Maastricht, The Netherlands.
  • Department of Surgery, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands.
  • Department of Internal Medicine, Division of Endocrinology and Metabolic Disease, Maastricht University Medical Center, 6229 HX Maastricht, The Netherlands.
  • NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, 6229 HX Maastricht, The Netherlands.
  • Department of Radiology and Nuclear Medicine, Mental Health and Neurosciences Research Institute (MHENS), Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht, The Netherlands.

Förderung

  • the institutional grants Siemens healthineers, Bayer healthcare

Zitieren

APA

Scheepers, M. H. M. C., Al-Difaie, Z. J. J., Bouvy, N. D., Havekes, B., & Postma, A. A. (2025). Four-Dimensional Dual-Energy Computed Tomography-Derived Parameters and Their Correlation with Thyroid Gland Functional Status. Tomography. https://doi.org/10.3390/tomography11030022

Vancouver

Scheepers MHMC, Al-Difaie ZJJ, Bouvy ND, Havekes B, Postma AA. Four-Dimensional Dual-Energy Computed Tomography-Derived Parameters and Their Correlation with Thyroid Gland Functional Status. Tomography. 2025. doi:10.3390/tomography11030022

BibTeX
@article{Scheepers2025,
  author = {Scheepers, Max H M C and Al-Difaie, Zaid J J and Bouvy, Nicole D and Havekes, Bas and Postma, Alida A},
  title = {Four-Dimensional Dual-Energy Computed Tomography-Derived Parameters and Their Correlation with Thyroid Gland Functional Status},
  journal = {Tomography},
  year = {2025},
  doi = {10.3390/tomography11030022}
}
Kostenlos starten →