EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Noise Reduction in Brain CT: A Comparative Study of Deep Learning and Hybrid Iterative Reconstruction Using Multiple Parameters

Yusuke Inoue iD, Hiroyasu Itoh, Hirofumi Hata, Hiroki Miyatake, Kohei Mitsui, Shunichi Uehara, Chisaki Masuda

Tomography · 2024

DOI: 10.3390/tomography10120147 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Tomography, 2024. Verfasst von Yusuke Inoue und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara 252-0374, Japan. Hauptthemen laut MEDLINE: Deep Learning, Phantoms, Imaging, Tomography, X-Ray Computed, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

We evaluated the noise reduction effects of deep learning reconstruction (DLR) and hybrid iterative reconstruction (HIR) in brain computed tomography (CT).

Methods

CT images of a 16 cm dosimetry phantom, a head phantom, and the brains of 11 patients were reconstructed using filtered backprojection (FBP) and various levels of DLR and HIR. The slice thickness was 5, 2.5, 1.25, and 0.625 mm. Phantom imaging was also conducted at various tube currents. The noise reduction ratio was calculated using FBP as the reference. For patient imaging, overall image quality was visually compared between DLR and HIR images that exhibited similar noise reduction ratios.

Results

The noise reduction ratio increased with increasing levels of DLR and HIR in phantom and patient imaging. For DLR, noise reduction was more pronounced with decreasing slice thickness, while such thickness dependence was less evident for HIR. Although the noise reduction effects of DLR were similar between the head phantom and patients, they differed for the dosimetry phantom. Variations between imaging objects were small for HIR. The noise reduction ratio was low at low tube currents for the dosimetry phantom using DLR; otherwise, the influence of the tube current was small. In terms of visual image quality, DLR outperformed HIR in 1.25 mm thick images but not in thicker images.

Conclusions

The degree of noise reduction using DLR depends on the slice thickness, tube current, and imaging object in addition to the level of DLR, which should be considered in the clinical use of DLR. DLR may be particularly beneficial for thin-slice imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningPhantoms, ImagingTomography, X-Ray ComputedBrainHumansMaleFemaleRadiographic Image Interpretation, Computer-AssistedSignal-To-Noise RatioMiddle AgedAgedAdultImage Processing, Computer-Assisted

Stichwörter der Autor:innen

braincomputed tomographydeep learning reconstructionhybrid iterative reconstructionimage noise

Autor:innen und Institutionen

  • Department of Diagnostic Radiology, Kitasato University School of Medicine, Sagamihara 252-0374, Japan.
  • Department of Radiology, Kitasato University Hospital, Sagamihara 252-0375, Japan.

ORCID-Profile: Yusuke Inoue

Zitieren

APA

Inoue, Y., Itoh, H., Hata, H., Miyatake, H., Mitsui, K., Uehara, S., & Masuda, C. (2024). Noise Reduction in Brain CT: A Comparative Study of Deep Learning and Hybrid Iterative Reconstruction Using Multiple Parameters. Tomography. https://doi.org/10.3390/tomography10120147

Vancouver

Inoue Y, Itoh H, Hata H, Miyatake H, Mitsui K, Uehara S, et al. Noise Reduction in Brain CT: A Comparative Study of Deep Learning and Hybrid Iterative Reconstruction Using Multiple Parameters. Tomography. 2024. doi:10.3390/tomography10120147

BibTeX
@article{Inoue2024,
  author = {Inoue, Yusuke and Itoh, Hiroyasu and Hata, Hirofumi and Miyatake, Hiroki and Mitsui, Kohei and Uehara, Shunichi and Masuda, Chisaki},
  title = {Noise Reduction in Brain CT: A Comparative Study of Deep Learning and Hybrid Iterative Reconstruction Using Multiple Parameters},
  journal = {Tomography},
  year = {2024},
  doi = {10.3390/tomography10120147}
}
Kostenlos starten →