EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhanced Diagnostic Accuracy of Pulmonary Embolism: Integrating Low-Dose CT with V/Q SPECT

Munassar Dakkam Lasloom, Mohamed Abuzaid iD

Tomography · 2024

DOI: 10.3390/tomography10080096 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Tomography, 2024. Verfasst von Munassar Dakkam Lasloom und 1 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Medicine Department, King Khalid Hospital, Najran P.O. Box 1120, Saudi Arabia. Hauptthemen laut MEDLINE: Pulmonary Embolism, Tomography, X-Ray Computed, Tomography, Emission-Computed, Single-Photon. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to retrospectively assess the benefits of combining low-dose computed tomography (LDCT) with ventilation/perfusion single-photon emission computed tomography (V/Q SPECT) for the diagnosis of pulmonary embolism (PE).

Methods

A retrospective analysis was performed on 92 patients with suspected PE who underwent V/Q SPECT with ldCT (V/Q SPECT CT) between January 2020 and December 2022 at King Khalid Hospital Najran. Data were collected using the hospital’s picture archiving and communication system. Scans were categorized on the basis of perfusion defects, matched or mismatched ventilation, and CT findings. The specificity of V/Q SPECT CT was compared with that of Q SPECT CT.

Results

This study included 92 patients (54 females and 38 males; median age, 53 years). The results demonstrated that V/Q SPECT CT had higher specificity (93%) than V/Q SPECT alone (88%). If CT had been used as a ventilation substitute, 21% of patients would have been reported to be positive for PE (8% false-positive), yielding a specificity of 60% for Q SPECT CT. These findings align with the existing literature, although discrepancies in specificity values were noted due to the different study designs and sample sizes.

Conclusion

This study highlights the enhanced specificity of V/Q SPECT CT compared to V/Q SPECT and Q SPECT CT alone. Including low-dose CT improves diagnostic accuracy by reducing false positives and providing detailed anatomical information. V/Q SPECT CT offers superior specificity in diagnosing PE compared with V/Q SPECT alone, supporting its use in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary EmbolismTomography, X-Ray ComputedTomography, Emission-Computed, Single-PhotonHumansFemaleMaleMiddle AgedRetrospective StudiesAgedSensitivity and SpecificityAdultRadiation DosageVentilation-Perfusion ScanAged, 80 and overVentilation-Perfusion Ratio

Stichwörter der Autor:innen

SPECTV/Q SPECTcomputed tomographydiagnosticpulmonary embolism

Autor:innen und Institutionen

  • Nuclear Medicine Department, King Khalid Hospital, Najran P.O. Box 1120, Saudi Arabia.
  • Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates.

ORCID-Profile: Mohamed Abuzaid

Zitieren

APA

Lasloom, M. D., & Abuzaid, M. (2024). Enhanced Diagnostic Accuracy of Pulmonary Embolism: Integrating Low-Dose CT with V/Q SPECT. Tomography. https://doi.org/10.3390/tomography10080096

Vancouver

Lasloom MD, Abuzaid M. Enhanced Diagnostic Accuracy of Pulmonary Embolism: Integrating Low-Dose CT with V/Q SPECT. Tomography. 2024. doi:10.3390/tomography10080096

BibTeX
@article{Lasloom2024,
  author = {Lasloom, Munassar Dakkam and Abuzaid, Mohamed},
  title = {Enhanced Diagnostic Accuracy of Pulmonary Embolism: Integrating Low-Dose CT with V/Q SPECT},
  journal = {Tomography},
  year = {2024},
  doi = {10.3390/tomography10080096}
}
Kostenlos starten →