Comparison of the Size Measurement of Gallbladder Polyps by Three Different Radiologists in Abdominal Ultrasonography
Tomography · 2024
DOI: 10.3390/tomography10070077 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Tomography, 2024. Verfasst von Kyu-Chong Lee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Armed Forces Capital Hospital, Seongnam 13574, Republic of Korea. Hauptthemen laut MEDLINE: Polyps, Ultrasonography, Radiologists. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
There is little information regarding the size measurement differences in gallbladder (GB) polyps performed by different radiologists on abdominal ultrasonography (US).
Aim
To reveal the differences in GB polyp size measurements performed by different radiologists on abdominal US.
Methods
From June to September 2022, the maximum diameter of 228 GB polyps was measured twice on abdominal US by one of three radiologists (a third-year radiology resident [reader A], a radiologist with 7 years of experience in abdominal US [reader B], and an abdominal radiologist with 8 years of experience in abdominal US [reader C]). Intra-reader agreements for polyp size measurements were assessed by intraclass correlation coefficient (ICC). A Bland–Altman plot was used to visualize the differences between the first and second size measurements in each reader.
Results
Reader A, reader B, and reader C evaluated 65, 77, and 86 polyps, respectively. The mean size of measured 228 GB polyps was 5.0 ± 1.9 mm. Except for the case where reader A showed moderate intra-reader agreement (0.726) for polyps with size ≤ 5 mm, all readers showed an overall high intra-reader reliability (reader A, ICC = 0.859; reader B, ICC = 0.947, reader C, ICC = 0.948), indicative of good and excellent intra-reader agreements. The 95% limit of agreement of reader A, B, and C was 1.9 mm of the mean in all three readers.
Conclusions
GB polyp size measurement on abdominal US showed good or excellent intra-reader agreements. However, size changes of approximately less than 1.9 mm should be interpreted carefully because these may be within the measurement error.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Armed Forces Capital Hospital, Seongnam 13574, Republic of Korea.
- Department of Radiology, Korea University Anam Hospital, 73 Geryeodae-ro, Seongbuk-Gu, Seoul 02841, Republic of Korea.
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-Ro, Seodaemun-Gu, Seoul 03722, Republic of Korea.
ORCID-Profile: Kyu-Chong Lee, Dong-Kyu Kim
Zitieren
APA
Lee, K. C., Kim, J. K., & Kim, D. K. (2024). Comparison of the Size Measurement of Gallbladder Polyps by Three Different Radiologists in Abdominal Ultrasonography. Tomography. https://doi.org/10.3390/tomography10070077
Vancouver
Lee KC, Kim JK, Kim DK. Comparison of the Size Measurement of Gallbladder Polyps by Three Different Radiologists in Abdominal Ultrasonography. Tomography. 2024. doi:10.3390/tomography10070077
BibTeX
@article{Lee2024,
author = {Lee, Kyu-Chong and Kim, Jin-Kyem and Kim, Dong-Kyu},
title = {Comparison of the Size Measurement of Gallbladder Polyps by Three Different Radiologists in Abdominal Ultrasonography},
journal = {Tomography},
year = {2024},
doi = {10.3390/tomography10070077}
}
EUVIMED