Impact of Deep Learning Denoising Algorithm on Diffusion Tensor Imaging of the Growth Plate on Different Spatial Resolutions
Tomography · 2024
DOI: 10.3390/tomography10040039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tomography, 2024. Verfasst von Laura Santos und 8 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Department, Columbia University Irving Medical Center, New York, NY 10032, USA. Hauptthemen laut MEDLINE: Deep Learning, Diffusion Tensor Imaging, Algorithms, Growth Plate. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NICHD NIH HHS, NIH HHS, Society for Pediatric Radiology Research.
Abstract (Originalsprache)
To assess the impact of a deep learning (DL) denoising reconstruction algorithm applied to identical patient scans acquired with two different voxel dimensions, representing distinct spatial resolutions, this IRB-approved prospective study was conducted at a tertiary pediatric center in compliance with the Health Insurance Portability and Accountability Act. A General Electric Signa Premier unit (GE Medical Systems, Milwaukee, WI) was employed to acquire two DTI (diffusion tensor imaging) sequences of the left knee on each child at 3T: an in-plane 2.0 × 2.0 mm2 with section thickness of 3.0 mm and a 2 mm3 isovolumetric voxel; neither had an intersection gap. For image acquisition, a multi-band DTI with a fat-suppressed single-shot spin-echo echo-planar sequence (20 non-collinear directions; b-values of 0 and 600 s/mm2) was utilized. The MR vendor-provided a commercially available DL model which was applied with 75% noise reduction settings to the same subject DTI sequences at different spatial resolutions. We compared DTI tract metrics from both DL-reconstructed scans and non-denoised scans for the femur and tibia at each spatial resolution. Differences were evaluated using Wilcoxon-signed ranked test and Bland–Altman plots. When comparing DL versus non-denoised diffusion metrics in femur and tibia using the 2 mm × 2 mm × 3 mm voxel dimension, there were no significant differences between tract count (p = 0.1, p = 0.14) tract volume (p = 0.1, p = 0.29) or tibial tract length (p = 0.16); femur tract length exhibited a significant difference (p < 0.01). All diffusion metrics (tract count, volume, length, and fractional anisotropy (FA)) derived from the DL-reconstructed scans, were significantly different from the non-denoised scan DTI metrics in both the femur and tibial physes using the 2 mm3 voxel size (p < 0.001). DL reconstruction resulted in a significant decrease in femorotibial FA for both voxel dimensions (p < 0.01). Leveraging denoising algorithms could address the drawbacks of lower signal-to-noise ratios (SNRs) associated with smaller voxel volumes and capitalize on their better spatial resolutions, allowing for more accurate quantification of diffusion metrics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology Department, Columbia University Irving Medical Center, New York, NY 10032, USA.
- GE Healthcare, New York, NY 10032, USA.
ORCID-Profile: Brendan Sullivan, Jaemin Shin, Marc R Lebel, Sachin Jambawalikar, Diego Jaramillo
Förderung
- NICHD NIH HHS
- NIH HHS
- Society for Pediatric Radiology Research
Zitieren
APA
Santos, L., Hsu, H. Y., Nelson, R. R., Sullivan, B., Shin, J., Fung, M., Lebel, M. R., Jambawalikar, S., & Jaramillo, D. (2024). Impact of Deep Learning Denoising Algorithm on Diffusion Tensor Imaging of the Growth Plate on Different Spatial Resolutions. Tomography. https://doi.org/10.3390/tomography10040039
Vancouver
Santos L, Hsu HY, Nelson RR, Sullivan B, Shin J, Fung M, et al. Impact of Deep Learning Denoising Algorithm on Diffusion Tensor Imaging of the Growth Plate on Different Spatial Resolutions. Tomography. 2024. doi:10.3390/tomography10040039
BibTeX
@article{Santos2024,
author = {Santos, Laura and Hsu, Hao-Yun and Nelson, Ronald R and Sullivan, Brendan and Shin, Jaemin and Fung, Maggie and Lebel, Marc R and Jambawalikar, Sachin and Jaramillo, Diego},
title = {Impact of Deep Learning Denoising Algorithm on Diffusion Tensor Imaging of the Growth Plate on Different Spatial Resolutions},
journal = {Tomography},
year = {2024},
doi = {10.3390/tomography10040039}
}
EUVIMED