Thermal Performance of Galvanized-Iron Sheet Sheds with Bio-Fiber Under-Roof Insulation Mats: A Tropical Field Study
Thermo · 22.11.2026 · 6 (4) · 89
DOI: 10.3390/thermo6040089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Thermo, online erschienen am 22.11.2026. Verfasst von Uthra Vasudevan und 3 weiteren Autor:innen. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Council of Architecture.
Abstract (Originalsprache)
Galvanized iron (GI) sheets are used for temporary labor sheds in tropical regions, but they provide minimal thermal resistance. This study assessed woven grass, jute, and coir mats installed as 10 mm insulation linings beneath a corrugated 0.5 mm GI roof in Chennai, India. Four test labor sheds under one roof, separated by a shed, were compared: a bare reference and the three mats. This study measured mat properties in the laboratory, calculated U-values, and estimated roof heat flux. Hourly temperatures were recorded continuously in all four sheds from 1 to 21 May 2026. The mats lowered the calculated U-value from 4.76 W m−2 K−1 (bare sheet) to 2.17–2.44 W m−2 K−1. On a reference day, 11 May, they reduced the peak interior-surface temperature by 1.87 to 3.13 K and the daytime-mean indoor air temperature by 1.22 to 1.92 K, with the grass mat performing best. Over the 21 measured days, the 24 h mean indoor air temperature was 0.99 to 1.64 K below the reference. Walls carried 73.5% of the calculated envelope thermal conductance, so the linings reduced envelope conductance by only 12.9% to 14.4%, and about 25 to 31 mm would be needed to meet the national roof criterion of 1.2 W m−2 K−1. Future work should examine thicker insulation, combined roof and wall insulation, and long-term performance. It should also test different lining materials in the same shed through rotation and repeat the experiments in additional sheds using the same materials to analyze the consistency and repeatability of the results. Untreated mats should also undergo fire-safety assessment and required treatments before deployment in occupied housing.
Förderung
- Council of Architecture
Zitieren
APA
Vasudevan, U., Priya, R. S., Kumar, G. R., & Senthil, R. (2026). Thermal Performance of Galvanized-Iron Sheet Sheds with Bio-Fiber Under-Roof Insulation Mats: A Tropical Field Study. Thermo, 6(4), 89. https://doi.org/10.3390/thermo6040089
Vancouver
Vasudevan U, Priya RS, Kumar GR, Senthil R. Thermal Performance of Galvanized-Iron Sheet Sheds with Bio-Fiber Under-Roof Insulation Mats: A Tropical Field Study. Thermo. 2026;6(4):89. doi:10.3390/thermo6040089
BibTeX
@article{Vasudevan2026,
author = {Vasudevan, Uthra and Priya, Radhakrishnan Shanthi and Kumar, Geetha Ramesh and Senthil, Ramalingam},
title = {Thermal Performance of Galvanized-Iron Sheet Sheds with Bio-Fiber Under-Roof Insulation Mats: A Tropical Field Study},
journal = {Thermo},
year = {2026},
volume = {6},
number = {4},
pages = {89},
doi = {10.3390/thermo6040089}
}