Analysis of Conductive Heat Transfer and Moisture Diffusion Through the Insulated Wall of a Refrigerated Warehouse

Laurențiu Mihail Constantin, Lavinia Grosu, Tiberiu Catalina, Adalia Andreea Percembli (Chelmuș), Daniel Taban, Claudia Ioniță, Alexandru Dobrovicescu

Thermo · 18.04.2026 · 6 (2) · 27

DOI: 10.3390/thermo6020027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Thermo, online erschienen am 18.04.2026. Verfasst von Laurențiu Mihail Constantin und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Romanian Ministry of Education and National University of Science and Technology Politehnica Bucharest through the PubArt Program..

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates steady-state conductive heat transfer and water-vapor diffusion through the external wall of a refrigerated warehouse with a specified load-bearing wall assembly. The formal analogy between heat conduction and mass diffusion is stated and used to establish a practical calculation framework for estimating heat and moisture ingress through multilayer cold-store walls. Calculation routines are presented to determine the temperature field and the corresponding water-vapor saturation and partial-pressure distributions across (and within) the insulation layer, enabling the identification of regions prone to interstitial condensation. The analysis highlights the roles of (i) the vapor diffusion resistance of the vapor barrier layer, (ii) the thermal resistance of the insulation, and (iii) key outdoor boundary conditions in governing condensation risk. Increasing insulation thermal resistance reduces external heat gains; however, it may also increase the likelihood of condensation in layers close to the cold side by lowering local temperatures and saturation pressures. Among external parameters, outdoor relative humidity exerts the strongest influence on interstitial condensation risk. For the investigated wall assembly, increasing outdoor relative humidity by 50% shifts the condensation onset location within the insulation toward mid-thickness. The effects of vapor barrier diffusion resistance, insulation thermal resistance, and changes in outdoor conditions (relative humidity, temperature, and wind speed) are reported in tabulated form and illustrated through pressure–position and temperature–position profiles.

Förderung

  • Romanian Ministry of Education and National University of Science and Technology Politehnica Bucharest through the PubArt Program.

Zitieren

APA

Constantin, L. M., Grosu, L., Catalina, T., (Chelmuș), A. A. P., Taban, D., Ioniță, C., & Dobrovicescu, A. (2026). Analysis of Conductive Heat Transfer and Moisture Diffusion Through the Insulated Wall of a Refrigerated Warehouse. Thermo, 6(2), 27. https://doi.org/10.3390/thermo6020027

Vancouver

Constantin LM, Grosu L, Catalina T, (Chelmuș) AAP, Taban D, Ioniță C, et al. Analysis of Conductive Heat Transfer and Moisture Diffusion Through the Insulated Wall of a Refrigerated Warehouse. Thermo. 2026;6(2):27. doi:10.3390/thermo6020027

BibTeX
@article{Constantin2026,
  author = {Constantin, Laurențiu Mihail and Grosu, Lavinia and Catalina, Tiberiu and (Chelmuș), Adalia Andreea Percembli and Taban, Daniel and Ioniță, Claudia and Dobrovicescu, Alexandru},
  title = {Analysis of Conductive Heat Transfer and Moisture Diffusion Through the Insulated Wall of a Refrigerated Warehouse},
  journal = {Thermo},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {27},
  doi = {10.3390/thermo6020027}
}
Kostenlos starten →