Kurz gefasst

Fachartikel in der Zeitschrift Thermo, online erschienen am 07.04.2026. Verfasst von Cuitlahuac Iriarte-Cornejo und 4 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Heating gases to high temperatures is essential for supplying energy to thermal and thermochemical processes. This study presents the optical–thermal design of a mini heliostat field coupled with a tubular solar receiver equipped with second optics, aiming to heat nitrogen to approximately 850 K. The secondary optical system redistributed up to 40% of the incident solar flux from the front to the rear surface of the receiver, improving radial temperature uniformity and significantly reducing thermal gradients along the tube wall. An overall optical efficiency of 65.25% was achieved, accounting for atmospheric attenuation, shading, blocking, and the cosine effect. A coupled computational model was developed by solving the conservation equations of mass, momentum, and energy, with the spatially resolved solar flux distribution obtained via ray tracing used as a thermal boundary condition. The simulation results, validated with an empirical correlation, include solar flux contours, nitrogen temperature distributions, surface temperatures, and heat transfer coefficients. The configuration with a 12 mm vertex spacing between secondary reflectors demonstrated the best thermal performance, reducing the maximum tube surface temperature by 11% and improving radial symmetry, while maintaining nitrogen outlet temperatures near the design target of 850 K. These results confirm the suitability of the system for high-temperature applications such as solar pyrolysis using nitrogen as the heat transfer fluid to deliver the required thermal energy.

Zitieren

APA

Iriarte-Cornejo, C., Durán, R. L., Maytorena, V. M., Hinojosa, J. F., & Moreno, S. F. (2026). Optical-Thermal Analysis of a Thermal Receiver with Second Optics for High-Temperature Gas Heating with Solar Tower System. Thermo, 6(2), 25. https://doi.org/10.3390/thermo6020025

Vancouver

Iriarte-Cornejo C, Durán RL, Maytorena VM, Hinojosa JF, Moreno SF. Optical-Thermal Analysis of a Thermal Receiver with Second Optics for High-Temperature Gas Heating with Solar Tower System. Thermo. 2026;6(2):25. doi:10.3390/thermo6020025

BibTeX
@article{IriarteCornejo2026,
  author = {Iriarte-Cornejo, Cuitlahuac and Durán, Resty L. and Maytorena, Victor M. and Hinojosa, Jesús F. and Moreno, Sául F.},
  title = {Optical-Thermal Analysis of a Thermal Receiver with Second Optics for High-Temperature Gas Heating with Solar Tower System},
  journal = {Thermo},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {25},
  doi = {10.3390/thermo6020025}
}
Kostenlos starten →