Developing Correction Methods for New Fibrogram-Based Length Measurements
Textiles · 07.08.2026 · 6 (3) · 96
DOI: 10.3390/textiles6030096 ↗Kurz gefasst
Fachartikel in der Zeitschrift Textiles, online erschienen am 07.08.2026. Verfasst von Md Harunur Rashid Bhuiyan und 3 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cotton Incorporated.
Abstract (Originalsprache)
Cotton fiber length is a key determinant of yarn quality, and High Volume Instrument (HVI) measurements are widely used to assess fiber length characteristics. Recent research has shown that the complete HVI fibrogram contains substantially more information than the conventional HVI-reported parameters, enabling reconstruction of the full fiber-length distribution and calculation of additional length-related parameters. Before these measurements can be adopted for routine use, calibration procedures are needed to ensure agreement among instruments. This study developed and evaluated calibration procedures for fibrogram-derived length parameters calculated from reconstructed fiber-length distributions. Three calibration reference cottons representing short, medium, and long fiber lengths were established and tested on four HVIs over a six-month period. Calibration equations were generated using two-point and three-point linear regressions between reference and observed measurements and applied to USDA evaluation cottons and commercial samples. Instrument stability, calibration frequency, and the use of comb checks were also investigated. Stability analysis showed that measurement drift within individual HVIs was small over the study period, indicating that frequent calibration is unnecessary under well-maintained operating conditions. Calibration improved agreement among HVIs for both conventional HVI-reported parameters and fibrogram-derived length parameters. Two-point and three-point calibration produced similar results, suggesting limited benefit from the additional medium-length calibration standard. Calibration frequency and comb checks had minimal impact on calibration efficacy. Overall, the proposed procedures improve consistency among HVIs and support practical implementation of new fibrogram-derived length measurements.
Förderung
- Cotton Incorporated
Zitieren
APA
Bhuiyan, M. H. R., Sayeed, M. A., Turner, C., & Abidi, N. (2026). Developing Correction Methods for New Fibrogram-Based Length Measurements. Textiles, 6(3), 96. https://doi.org/10.3390/textiles6030096
Vancouver
Bhuiyan MHR, Sayeed MA, Turner C, Abidi N. Developing Correction Methods for New Fibrogram-Based Length Measurements. Textiles. 2026;6(3):96. doi:10.3390/textiles6030096
BibTeX
@article{Bhuiyan2026,
author = {Bhuiyan, Md Harunur Rashid and Sayeed, Md Abu and Turner, Christopher and Abidi, Noureddine},
title = {Developing Correction Methods for New Fibrogram-Based Length Measurements},
journal = {Textiles},
year = {2026},
volume = {6},
number = {3},
pages = {96},
doi = {10.3390/textiles6030096}
}
EUVIMED