Mechatronic Design, Biomechanical Analysis, and Kinematic Validation of a Continuous Passive Motion Slider–Crank–Lead Screw System for Lower-Limb Rehabilitation: From Post-Stroke Therapy to Potential Post-Spaceflight Reconditioning
Technologies · 16.11.2026 · 14 (11) · 757
DOI: 10.3390/technologies14110757 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technologies, online erschienen am 16.11.2026. Verfasst von Adrian Nacarino und 9 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Ricardo Palma.
Themen: Schlaganfall
Abstract (Originalsprache)
This study developed and preliminarily validated a robotic Continuous Passive Motion (CPM) system intended for lower-limb rehabilitation in post-stroke adult patients with hemiplegia. Building upon a previous redesign and simulation stage using a virtual patient model, an adjustable structure made of AISI 316L stainless steel was fabricated, integrating the mechanical, electronic, and control subsystems for passive knee and ankle mobilization through a lead screw mechanism driven by a NEMA23 stepper motor, a TB6600 driver, and an ESP32 microcontroller operating under an open-loop feedforward control scheme. As a preliminary stage prior to clinical evaluation, functional validation was conducted through three knee therapy tests, two with a healthy adult volunteer and one under unloaded conditions, using different angular ranges (90–130°, 30–26°, and 50–70°). The device successfully executed the programmed movements without mechanical or electronic failures, completing all three repetitions in each session and recording observed differences ranging from 2.00% to 11.54% between the programmed and measured joint angles. These results demonstrate the preliminary technical feasibility of the proposed prototype. The present validation was limited to a single adult volunteer and three knee-motion tests. Future work will include validation with volunteers representing different anthropometric profiles (1.55–1.75 m), verification of emergency stop response times below 100 ms, and the incorporation of encoder-based position feedback as preliminary steps toward subsequent clinical evaluation.
Förderung
- Universidad Ricardo Palma
Zitieren
APA
Nacarino, A., Suclupe, H., Sandoval, C., Martel, C., Cornejo, J., Murillo, M., Borja, J., Rey, J. A., Vargas, M., & Palomares, R. (2026). Mechatronic Design, Biomechanical Analysis, and Kinematic Validation of a Continuous Passive Motion Slider–Crank–Lead Screw System for Lower-Limb Rehabilitation: From Post-Stroke Therapy to Potential Post-Spaceflight Reconditioning. Technologies, 14(11), 757. https://doi.org/10.3390/technologies14110757
Vancouver
Nacarino A, Suclupe H, Sandoval C, Martel C, Cornejo J, Murillo M, et al. Mechatronic Design, Biomechanical Analysis, and Kinematic Validation of a Continuous Passive Motion Slider–Crank–Lead Screw System for Lower-Limb Rehabilitation: From Post-Stroke Therapy to Potential Post-Spaceflight Reconditioning. Technologies. 2026;14(11):757. doi:10.3390/technologies14110757
BibTeX
@article{Nacarino2026,
author = {Nacarino, Adrian and Suclupe, Harnnol and Sandoval, Carol and Martel, Cesar and Cornejo, Jose and Murillo, Margarita and Borja, Jeanette and Rey, Josue Alata and Vargas, Mariela and Palomares, Ricardo},
title = {Mechatronic Design, Biomechanical Analysis, and Kinematic Validation of a Continuous Passive Motion Slider–Crank–Lead Screw System for Lower-Limb Rehabilitation: From Post-Stroke Therapy to Potential Post-Spaceflight Reconditioning},
journal = {Technologies},
year = {2026},
volume = {14},
number = {11},
pages = {757},
doi = {10.3390/technologies14110757}
}
EUVIMED