EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Direct Cooling Strategies for Hydrogen Refueling Stations

Santiago Laín, Marcos Larrosa

Technologies · 02.08.2026 · 14 (8) · 478

DOI: 10.3390/technologies14080478 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technologies, online erschienen am 02.08.2026. Verfasst von Santiago Laín und 1 weiteren Autor:innen. Die Arbeit nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Vicerrectoría de Investigación, Innovación y Emprendimiento of Universidad Autónoma de Occidente.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the potential for reducing or eliminating conventional pre-cooling requirements in hydrogen refueling stations (HRS) through the integration of turboexpanders, using a combined thermodynamic modeling and Computational Fluid Dynamics (CFD) approach. A key novelty of the present work is the explicit comparison between constant and variable isentropic efficiency formulations, enabling a more realistic representation of turboexpander performance under the highly transient operating conditions characteristic of hydrogen refueling processes. A simplified thermodynamic model is first used to estimate the transient inlet conditions associated with different pressure-reduction strategies, which are subsequently imposed as boundary conditions for three-dimensional CFD simulations of the fast filling of a 70 MPa Type III hydrogen cylinder. The CFD methodology is validated against experimental data for conventional refueling under prescribed inlet-temperature conditions, while the sensitivity of the predictions to turbulence modeling is also assessed. The validated framework is then applied to compare conventional throttling, a single turboexpander with constant isentropic efficiency, and a parallel-expander configuration accounting for variable off-design efficiency. The CFD predictions indicate that turboexpander-assisted refueling can reduce hydrogen heating, with the parallel-expander configuration yielding a final average hydrogen temperature approximately 15 K lower than that predicted for conventional throttling.

Förderung

  • Vicerrectoría de Investigación, Innovación y Emprendimiento of Universidad Autónoma de Occidente

Zitieren

APA

Laín, S., & Larrosa, M. (2026). Evaluation of Direct Cooling Strategies for Hydrogen Refueling Stations. Technologies, 14(8), 478. https://doi.org/10.3390/technologies14080478

Vancouver

Laín S, Larrosa M. Evaluation of Direct Cooling Strategies for Hydrogen Refueling Stations. Technologies. 2026;14(8):478. doi:10.3390/technologies14080478

BibTeX
@article{Lan2026,
  author = {Laín, Santiago and Larrosa, Marcos},
  title = {Evaluation of Direct Cooling Strategies for Hydrogen Refueling Stations},
  journal = {Technologies},
  year = {2026},
  volume = {14},
  number = {8},
  pages = {478},
  doi = {10.3390/technologies14080478}
}