EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Single-Point Adaptive Gaze-to-Cursor Correction Pipeline for Low-Burden Dwell-Based Eye-Tracking Interfaces: Design and Human Evaluation

Paweł Krowicki, Fryderyk Gajdzik, Roman Olejniczak, Zofia Tomala, Grzegorz Żurek

Technologies · 19.07.2026 · 14 (7) · 444

DOI: 10.3390/technologies14070444 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technologies, online erschienen am 19.07.2026. Verfasst von Paweł Krowicki und 4 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Eye-controlled interfaces can support communication and selection tasks when physical interaction is difficult, but conventional multi-point calibration may be burdensome for users who fatigue quickly or have severe motor limitations. This study operationally evaluates a low-burden single-point adaptive gaze-to-cursor correction pipeline for a dwell-based selection interface.

Methods

The pipeline combines central single-point offset estimation, robust median/median absolute deviation (MAD) sample handling, recorded-stream jump rejection, exponential moving average filtering, dwell-based selection, and post-selection offset adaptation. It was evaluated using application-level gaze-to-cursor coordinates from 43 participants across 129 sessions. The primary endpoint was target-proximity Root Mean Square (RMS) during automatically logged dwell-active selection periods. Because these periods were defined by the pipeline’s online state, the endpoint was algorithm-conditioned. Whole-quiz RMS was analyzed as a secondary full-trajectory descriptor rather than as independent validation.

Results

Averaged across three repeated measurements, target-proximity RMS during dwell-active periods decreased from 193.40 pixels (px) (approximately 3.15°) for the recorded uncorrected coordinates to 56.02 px (0.91°) for the complete pipeline output. The mean reduction was 137.38 px (95% confidence interval (CI), 116.59–158.17 px; Cohen’s dz = 2.03), and all 43 participants showed a reduction.

Conclusions

The results support the practical feasibility of the complete correction pipeline for target localization in the evaluated dwell-based interface. They do not independently validate native eye-tracker accuracy or establish superiority over conventional multi-point calibration.

Zitieren

APA

Krowicki, P., Gajdzik, F., Olejniczak, R., Tomala, Z., & Żurek, G. (2026). A Single-Point Adaptive Gaze-to-Cursor Correction Pipeline for Low-Burden Dwell-Based Eye-Tracking Interfaces: Design and Human Evaluation. Technologies, 14(7), 444. https://doi.org/10.3390/technologies14070444

Vancouver

Krowicki P, Gajdzik F, Olejniczak R, Tomala Z, Żurek G. A Single-Point Adaptive Gaze-to-Cursor Correction Pipeline for Low-Burden Dwell-Based Eye-Tracking Interfaces: Design and Human Evaluation. Technologies. 2026;14(7):444. doi:10.3390/technologies14070444

BibTeX
@article{Krowicki2026,
  author = {Krowicki, Paweł and Gajdzik, Fryderyk and Olejniczak, Roman and Tomala, Zofia and Żurek, Grzegorz},
  title = {A Single-Point Adaptive Gaze-to-Cursor Correction Pipeline for Low-Burden Dwell-Based Eye-Tracking Interfaces: Design and Human Evaluation},
  journal = {Technologies},
  year = {2026},
  volume = {14},
  number = {7},
  pages = {444},
  doi = {10.3390/technologies14070444}
}
Kostenlos starten →