Micro-Attention CNN Hybrid Architecture for Real-Time Stress Detection Using Minimalistic Bio-Signals
Technologies · 13.05.2026 · 14 (5) · 300
DOI: 10.3390/technologies14050300 ↗Kurz gefasst
Fachartikel in der Zeitschrift Technologies, online erschienen am 13.05.2026. Verfasst von Chaymae Yahyati und 4 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Real-time psychological stress detection on wearable and edge devices requires models that are accurate, computationally efficient, and small enough for on-device deployment. This paper proposes a Micro-Attention CNN Hybrid Architecture for stress recognition using wearable bio-signals. The model uses six sensor channels, namely tri-axial acceleration, electrodermal activity, heart rate, and skin temperature, and classifies three stress levels: no stress, low stress, and high stress. This study is conducted on a public wearable sensor dataset collected from 15 nurses during hospital work, providing a realistic benchmark for continuous stress monitoring under practical conditions. The proposed architecture combines one-dimensional and depthwise separable convolutions with a lightweight attention module to emphasize the most informative temporal patterns in short multivariate signal segments. To support deployment on resource-constrained devices, we further apply structured pruning, selective quantization-aware training, and post-training quantization. The full-precision model achieves a Macro-F1 score of 99.63%, while the final compressed model retains 98.03% Macro-F1 with a model size of 1.76 kilobytes and a CPU inference latency of 0.40 ms. Additional analyses show that most residual errors occur near the boundary between low stress and neighboring classes, while simple post-compression calibration improves reliability. These results demonstrate that accurate and low-latency stress detection using wearable bio-signals is feasible on compact edge hardware without transmitting raw sensor streams off-device.
Zitieren
APA
Yahyati, C., Lamaakal, I., Maleh, Y., Makkaoui, K. E., & Ouahbi, I. (2026). Micro-Attention CNN Hybrid Architecture for Real-Time Stress Detection Using Minimalistic Bio-Signals. Technologies, 14(5), 300. https://doi.org/10.3390/technologies14050300
Vancouver
Yahyati C, Lamaakal I, Maleh Y, Makkaoui KE, Ouahbi I. Micro-Attention CNN Hybrid Architecture for Real-Time Stress Detection Using Minimalistic Bio-Signals. Technologies. 2026;14(5):300. doi:10.3390/technologies14050300
BibTeX
@article{Yahyati2026,
author = {Yahyati, Chaymae and Lamaakal, Ismail and Maleh, Yassine and Makkaoui, Khalid El and Ouahbi, Ibrahim},
title = {Micro-Attention CNN Hybrid Architecture for Real-Time Stress Detection Using Minimalistic Bio-Signals},
journal = {Technologies},
year = {2026},
volume = {14},
number = {5},
pages = {300},
doi = {10.3390/technologies14050300}
}
EUVIMED