EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Aerodynamic Mitigation of Vortex-Induced Vibration for a Wide Streamlined Box Girder: An Experimental Case Study

Rujie Cao, Wenkai Du, Guangzhong Gao, Lu Yu, Hua Bai, Jianming Hao, Guojun Yang, Jiawu Li

Symmetry · 29.07.2026 · 18 (8) · 1293

DOI: 10.3390/sym18081293 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Symmetry, online erschienen am 29.07.2026. Verfasst von Rujie Cao und 7 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vortex-induced vibration (VIV) poses a significant serviceability concern for wide streamlined box girders of long-span suspension bridges. This study investigates the VIV performance and aerodynamic mitigation of a wide streamlined box girder with a width-to-depth ratio (B/D) of approximately 10 through sectional model wind tunnel testing. The original cross-section was found to exhibit pronounced heaving and torsional VIV at positive wind angles of attack, with amplitudes considerably exceeding the prescribed serviceability limits. A systematic experimental investigation was conducted to evaluate the influence of three geometric parameters, i.e., wind fairing inclination angle, inspection rail position, and pedestrian railing porosity and panel arrangement, on VIV performance. Experimental results demonstrate that reducing the wind fairing inclination angle from 65° to 45° is the most effective mitigation measure. An appropriate porosity of the pedestrian railing is shown to substantially improve VIV performance. Furthermore, under equivalent overall porosity, a uniformly distributed alternation of solid and ventilated panels yields markedly superior VIV suppression compared with continuously sealed arrangements. Subsequent flutter and aerostatic wind tunnel tests confirm that the recommended cross-section preserves the favorable flutter stability and aerostatic performance of the original design. Strouhal number analysis reveals that the VIV lock-in is governed by St ≈ 0.12. Notably, the St number obtained from the pitching moment coefficient is nearly twice that obtained from the lift coefficient.

Zitieren

APA

Cao, R., Du, W., Gao, G., Yu, L., Bai, H., Hao, J., Yang, G., & Li, J. (2026). Aerodynamic Mitigation of Vortex-Induced Vibration for a Wide Streamlined Box Girder: An Experimental Case Study. Symmetry, 18(8), 1293. https://doi.org/10.3390/sym18081293

Vancouver

Cao R, Du W, Gao G, Yu L, Bai H, Hao J, et al. Aerodynamic Mitigation of Vortex-Induced Vibration for a Wide Streamlined Box Girder: An Experimental Case Study. Symmetry. 2026;18(8):1293. doi:10.3390/sym18081293

BibTeX
@article{Cao2026,
  author = {Cao, Rujie and Du, Wenkai and Gao, Guangzhong and Yu, Lu and Bai, Hua and Hao, Jianming and Yang, Guojun and Li, Jiawu},
  title = {Aerodynamic Mitigation of Vortex-Induced Vibration for a Wide Streamlined Box Girder: An Experimental Case Study},
  journal = {Symmetry},
  year = {2026},
  volume = {18},
  number = {8},
  pages = {1293},
  doi = {10.3390/sym18081293}
}
Kostenlos starten →