Carbon-Constrained Operational Adequacy Assessment for Sustainable Power Systems with High Renewable Penetration
Sustainability · 20.11.2026 · 18 (22) · 11828
DOI: 10.3390/su182211828 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sustainability, online erschienen am 20.11.2026. Verfasst von Penghan Li und 3 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: science and technology project of the Northwest Branch of State Grid Corporation of China.
Abstract (Originalsprache)
The transition toward sustainable power systems requires generation adequacy assessments that account for both renewable uncertainty and carbon emission constraints on usable thermal capacity. This study develops a framework that integrates carbon-constrained day-ahead unit commitment (UC), schedule-informed allocation of a separate assessment-stage emission cap, and a probabilistic transformation of thermal capacity. The UC schedule establishes hourly emissions and incremental emission potential. The assessment cap is allocated in proportion to that potential, after which a joint distribution of available thermal capacity and full-output emission potential is constructed. An expectation-calibrated truncation threshold and an approximate emission-to-capacity mapping produce an effective-capacity distribution that is convolved with multi-state wind output to calculate hourly loss-of-load probability (LOLP) and expected energy not supplied (EENS). In a modified IEEE RTS-79 case, the mapping closely matches a unit-level emission-constrained reference across the dominant outage states. The UC-informed allocation avoids hourly emission limits inconsistent with the scheduled operating conditions, while the proposed proportional rule yields the smallest maximum hourly relative effective-capacity loss among the three UC-based allocation rules and maintains competitive overall reliability performance. Under 1920 MW of installed wind, relaxing the assessment cap from 19,000 to 20,000 tCO2/day reduces daily mean LOLP from 0.0194 to 0.0107 and daily EENS from 43.03 to 31.30 MWh. Carbon restrictions affect generation adequacy unevenly across hours and can shift the most critical operating periods, highlighting the importance of integrating low-carbon operating requirements with time-resolved probabilistic adequacy assessment to identify supply risks in renewable-rich power systems.
Förderung
- science and technology project of the Northwest Branch of State Grid Corporation of China
Zitieren
APA
Li, P., Li, Q., Wang, Y., & Cui, W. (2026). Carbon-Constrained Operational Adequacy Assessment for Sustainable Power Systems with High Renewable Penetration. Sustainability, 18(22), 11828. https://doi.org/10.3390/su182211828
Vancouver
Li P, Li Q, Wang Y, Cui W. Carbon-Constrained Operational Adequacy Assessment for Sustainable Power Systems with High Renewable Penetration. Sustainability. 2026;18(22):11828. doi:10.3390/su182211828
BibTeX
@article{Li2026,
author = {Li, Penghan and Li, Qinyi and Wang, Ying and Cui, Wei},
title = {Carbon-Constrained Operational Adequacy Assessment for Sustainable Power Systems with High Renewable Penetration},
journal = {Sustainability},
year = {2026},
volume = {18},
number = {22},
pages = {11828},
doi = {10.3390/su182211828}
}
EUVIMED