Fully Transient Analytical Solutions for Organic Contaminant Transport Through GMB/CCL and GMB/GCL Composite Liners Considering Advection, Degradation and Thermodiffusion for Sustainable Mitigation
Sustainability · 18.07.2026 · 18 (14) · 7354
DOI: 10.3390/su18147354 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sustainability, online erschienen am 18.07.2026. Verfasst von Yun He und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Wuhan, Science and Technology Research Project of Hubei Provincial Department of Education.
Abstract (Originalsprache)
This paper presents fully transient analytical solutions for organic contaminant transport through composite liner systems consisting of a geomembrane (GMB) underlain by either a compacted clay liner (CCL) or a geosynthetic clay liner (GCL). The proposed solutions simultaneously account for three key mechanisms, namely advection due to GMB defects and wrinkles, first-order degradation, and thermodiffusion induced by temperature gradients. The solutions provide steady-state temperature distribution, transient contaminant concentration profiles, mass flux, and cumulative mass outflow at the base of the liner. The analytical solutions are rigorously verified against experimental thermodiffusion data from the literature, an existing analytical solution, and a numerical model using COMSOL Multiphysics 5.4. A parametric study is conducted to investigate the effects of thermodiffusion, Soret coefficient, and thermal conductivity on benzene transport. Results show that thermodiffusion substantially increases benzene outflow; neglecting it may lead to unconservative liner design. The benzene transport rate increases almost linearly with the Soret coefficient. The thermal conductivity of the GMB and GCL significantly affects benzene transport in the GMB/GCL system, while the thermal conductivities of the GMB and CCL have negligible effects on the GMB/CCL system. The proposed analytical solutions enable rapid parametric analysis, preliminary liner design, environmental risk assessment, and early warning. By enabling rapid comparison of GMB/CCL versus GMB/GCL systems (material selection), optimization of clay layer thickness for required breakthrough time (thickness optimization), and quantification of thermal effects on contaminant flux (temperature control), the solutions serve as an efficient tool for sustainable liner design.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Wuhan
- Science and Technology Research Project of Hubei Provincial Department of Education
Zitieren
APA
He, Y., Lyu, W., Qiu, J., Wu, J., & Pu, H. (2026). Fully Transient Analytical Solutions for Organic Contaminant Transport Through GMB/CCL and GMB/GCL Composite Liners Considering Advection, Degradation and Thermodiffusion for Sustainable Mitigation. Sustainability, 18(14), 7354. https://doi.org/10.3390/su18147354
Vancouver
He Y, Lyu W, Qiu J, Wu J, Pu H. Fully Transient Analytical Solutions for Organic Contaminant Transport Through GMB/CCL and GMB/GCL Composite Liners Considering Advection, Degradation and Thermodiffusion for Sustainable Mitigation. Sustainability. 2026;18(14):7354. doi:10.3390/su18147354
BibTeX
@article{He2026,
author = {He, Yun and Lyu, Wei-Dong and Qiu, Jin-Wei and Wu, Jing and Pu, He-Fu},
title = {Fully Transient Analytical Solutions for Organic Contaminant Transport Through GMB/CCL and GMB/GCL Composite Liners Considering Advection, Degradation and Thermodiffusion for Sustainable Mitigation},
journal = {Sustainability},
year = {2026},
volume = {18},
number = {14},
pages = {7354},
doi = {10.3390/su18147354}
}
EUVIMED