Hybridisation of District Heating in Existing Office Buildings Using Air-to-Water Heat Pumps: A Case Study on Energy and Performance

Alexandru Dorca, Ioan Sarbu

Sustainability · 15.05.2026 · 18 (10) · 4965

DOI: 10.3390/su18104965 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sustainability, online erschienen am 15.05.2026. Verfasst von Alexandru Dorca und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates integrating an air-to-water heat pump (HP) into an existing office building served by a district heating (DH) system to improve energy performance and reduce environmental impact. The system was modelled using Polysun software, considering two operating scenarios: a conventional configuration based solely on DH and a hybrid configuration combining DH with a HP. The analysis was performed using hourly simulations over a typical meteorological year, allowing a detailed evaluation of system behaviour under varying climatic conditions. The results indicate that the hybrid system reduces total energy consumption by approximately 24%, while natural gas consumption decreases by about 36%. Although electricity consumption increases due to HP operation, the overall energy performance is significantly improved. The HP operates efficiently within the analysed temperature range, with COP values ranging from 1.8 to 3.0 and a seasonal performance coefficient of approximately 3.6. The system ensures full coverage of the heating demand, with a negligible deficit, confirming appropriate sizing and control strategy. From an environmental perspective, the hybrid configuration results in approximately 29 t CO2 per year less than the conventional system. These results demonstrate that integrating HPs into existing DH systems can represent a viable solution for similar buildings under comparable operating conditions. Beyond the quantified energy and environmental benefits, the novelty of the study lies in evaluating a hybrid solution under real operating conditions affected by DH instability. The results highlight practical implications for system resilience, operational flexibility, and the applicability of this retrofit strategy to existing buildings connected to conventional DH networks.

Zitieren

APA

Dorca, A., & Sarbu, I. (2026). Hybridisation of District Heating in Existing Office Buildings Using Air-to-Water Heat Pumps: A Case Study on Energy and Performance. Sustainability, 18(10), 4965. https://doi.org/10.3390/su18104965

Vancouver

Dorca A, Sarbu I. Hybridisation of District Heating in Existing Office Buildings Using Air-to-Water Heat Pumps: A Case Study on Energy and Performance. Sustainability. 2026;18(10):4965. doi:10.3390/su18104965

BibTeX
@article{Dorca2026,
  author = {Dorca, Alexandru and Sarbu, Ioan},
  title = {Hybridisation of District Heating in Existing Office Buildings Using Air-to-Water Heat Pumps: A Case Study on Energy and Performance},
  journal = {Sustainability},
  year = {2026},
  volume = {18},
  number = {10},
  pages = {4965},
  doi = {10.3390/su18104965}
}
Kostenlos starten →