A Comparative Study of Load Frequency Regulation for Multi-Area Interconnected Grids Using Integral Controller

Awadh Ba Wazir, Ahmed Althobiti, Abdullah A. Alhussainy, Sultan Alghamdi, Mahendiran Vellingiri, Thangam Palaniswamy, Muhyaddin Rawa

Sustainability · 01.05.2024 · 16 (9) · 3808

DOI: 10.3390/su16093808 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sustainability, online erschienen am 01.05.2024. Verfasst von Awadh Ba Wazir und 6 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Scientific Research (DSR) at King Abdulaziz University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present paper provides an optimal design for load frequency control (LFC) in the interconnected power system. To obtain an adequate LFC response alongside shortening implementation time and minimizing costs, an integral (I) controller is used. A deep analysis of the I controller-based LFC is presented. At first, a two-area interconnected power system is used, and to enhance the LFC response, the I controller and frequency bias parameters are optimized using three novel optimization algorithms, which are the incomprehensible but intelligible-in-time logic algorithm (ILA), the coati optimization algorithm (COA), and the brown-bear optimization algorithm (BOA). Also, five well-known techniques, namely, particle swarm optimization (PSO), genetic algorithm (GA), simulated annealing (SA), pattern search (PS), and nonlinear programming (NP), are used. A new objective function utilizing the integral of squared error (ISE), settling time, settling-max, and settling-min of the dynamic response is used to increase the efficacy of estimating the parameters. The presented results in this paper showed that the optimized I controller outperforms the classic I controller. After considering a load change in one area by 18.75%, the optimized I controller achieved the lowest ISE values. ISE values were: 0.00582, 0.00179, 0.00176, 0.00178, 0.00321, 0.00304, 0.00179, 0.00185, and 0.00181, for classic I, PSO-I, GA-I, SA-I, PS-I, NP-I, ILA-I, COA-I, and BOA-I. Then, the proposed method is applied to a nonlinear two-area system, demonstrating that the proposed strategies can deal with nonlinearity. As the purpose of the hybrid power system is to create a robust energy infrastructure that adheres to sustainability standards, the proposed algorithms are analyzed in a three-area multi-source power system comprising renewable energy sources (RESs) such as photovoltaic (PV) and wind turbine (WT), a battery energy storage system (BESS), and an electric vehicle (EV).

Förderung

  • Deanship of Scientific Research (DSR) at King Abdulaziz University

Zitieren

APA

Wazir, A. B., Althobiti, A., Alhussainy, A. A., Alghamdi, S., Vellingiri, M., Palaniswamy, T., & Rawa, M. (2024). A Comparative Study of Load Frequency Regulation for Multi-Area Interconnected Grids Using Integral Controller. Sustainability, 16(9), 3808. https://doi.org/10.3390/su16093808

Vancouver

Wazir AB, Althobiti A, Alhussainy AA, Alghamdi S, Vellingiri M, Palaniswamy T, et al. A Comparative Study of Load Frequency Regulation for Multi-Area Interconnected Grids Using Integral Controller. Sustainability. 2024;16(9):3808. doi:10.3390/su16093808

BibTeX
@article{Wazir2024,
  author = {Wazir, Awadh Ba and Althobiti, Ahmed and Alhussainy, Abdullah A. and Alghamdi, Sultan and Vellingiri, Mahendiran and Palaniswamy, Thangam and Rawa, Muhyaddin},
  title = {A Comparative Study of Load Frequency Regulation for Multi-Area Interconnected Grids Using Integral Controller},
  journal = {Sustainability},
  year = {2024},
  volume = {16},
  number = {9},
  pages = {3808},
  doi = {10.3390/su16093808}
}