Enhancement of Indoor Air Quality with a Displacement Ventilation System Comprising a 4-Way Fan Coil Unit and Multiple Air Purifiers
Sustainability · 20.02.2024 · 16 (5) · 1740
DOI: 10.3390/su16051740 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sustainability, online erschienen am 20.02.2024. Verfasst von Su-Hoon Park und 7 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BK21 FOUR (Fostering Outstanding Universities for Research) program, National Research Foundation (NRF), Ministry of Education of Korea.
Abstract (Originalsprache)
In indoor spaces without mechanical ventilation systems, a common approach involves using a ceiling-mounted 4-way fan coil unit (4WFCU) to regulate indoor temperature and placing floor-level air purifiers (APs) to remove indoor pollutants. This study introduces a differentiated displacement ventilation system (DVS) that connects multiple APs to the 4WFCU using ductwork. The age of air was compared between the case where the newly designed DVS was implemented and the reference case where 4WFCU and APs operated independently. When there were no obstacles in the office central area, the reference system exhibited a lower age of air. Conversely, when obstacles such as desks and partitions were present in the central area, the proposed DVS was found to improve indoor air quality. The DVS resulted in minimal interference among pathlines of the air discharged from multiple floor-level APs and their efficient suction through the ceiling-mounted 4WFCU and diffusers, significantly reducing stagnant air zones, while pathlines of the air discharged from the 4WFCU and APs interfered significantly when they operated independently, leading to larger stagnant areas in the air distribution. Therefore, modifying office spaces with ceiling-mounted 4WFCUs using the proposed DVS is anticipated to substantially enhance indoor air quality through a straightforward installation process.
Förderung
- BK21 FOUR (Fostering Outstanding Universities for Research) program
- National Research Foundation (NRF)
- Ministry of Education of Korea
Zitieren
APA
Park, S., An, I., Lee, Y., Cho, S., Lee, C., Seo, S., Lee, H., & Yook, S. (2024). Enhancement of Indoor Air Quality with a Displacement Ventilation System Comprising a 4-Way Fan Coil Unit and Multiple Air Purifiers. Sustainability, 16(5), 1740. https://doi.org/10.3390/su16051740
Vancouver
Park S, An I, Lee Y, Cho S, Lee C, Seo S, et al. Enhancement of Indoor Air Quality with a Displacement Ventilation System Comprising a 4-Way Fan Coil Unit and Multiple Air Purifiers. Sustainability. 2024;16(5):1740. doi:10.3390/su16051740
BibTeX
@article{Park2024,
author = {Park, Su-Hoon and An, Ik-Hyun and Lee, Yong-Ho and Cho, Sang-Hyun and Lee, Chang-Hoon and Seo, Sang-Bum and Lee, Hyun-Woo and Yook, Se-Jin},
title = {Enhancement of Indoor Air Quality with a Displacement Ventilation System Comprising a 4-Way Fan Coil Unit and Multiple Air Purifiers},
journal = {Sustainability},
year = {2024},
volume = {16},
number = {5},
pages = {1740},
doi = {10.3390/su16051740}
}