Energy and Exergy-Based Efficiency, Sustainability and Economic Assessment towards Improved Energy Management of a Thermal Power Plant: A Case Study
Sustainability · 20.03.2023 · 15 (6) · 5452
DOI: 10.3390/su15065452 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sustainability, online erschienen am 20.03.2023. Verfasst von Md Hasan Maruf und 8 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universiti Kebangsaan Malaysia (UKM).
Abstract (Originalsprache)
This paper explores the energy management of a natural gas-based thermal power plant, with a focus on improving its efficiency, sustainability, and economic feasibility. The study uses the Ashuganj Power Station Company Limited (APSCL) in Bangladesh as a case study. To evaluate the efficiency of the APSCL, both energy and exergy perspectives are considered, and sustainability is assessed through exergetic parameters. The plant’s economic feasibility is analyzed based on its fuel costs and operational losses. The results of the study indicate that the energy and exergy efficiencies of the APSCL vary from 32.97% to 33.21% and from 32.63% to 32.87%, respectively, for steam turbines and from 39.77% to 56.98% and from 39.36% to 56.40%, respectively, for combined cycle power plants (CCPP) during 2016–2021. The slightly lower efficiency in exergy calculations accounts for the system loss incurred over time, which is often omitted in efficiency calculations using energy parameters. To measure the sustainability of the APSCL, eight key indicators are used: the depletion number, exergy sustainable index, cumulative exergy loss, relative irreversibility, lack of production, the wasted exergy ratio, environmental effect factor, and improvement potential. The results indicate that APSCL still has opportunities for improvement in terms of sustainability, with 50% of the fuel being depleted in the plant, contributing to a sustainable index of 2.00 and cumulative exergy loss varying between 48.59 and 21.17. Regarding financial costs and losses, APSCL has experienced an increasing trend in the price of electricity generated. However, by implementing intelligent maintenance practices and upgrading equipment in a timely manner, it is possible to minimize costs and increase exergy output, reducing the per-unit fuel requirement for electricity production and the global carbon footprint significantly.
Förderung
- Universiti Kebangsaan Malaysia (UKM)
Zitieren
APA
Maruf, M. H., July, S. A., Rabbani, M., Sahrani, S., Lipu, M. S. H., Sarker, M. R., Ashique, R. H., Kabir, M. S., & Shihavuddin, A. S. M. (2023). Energy and Exergy-Based Efficiency, Sustainability and Economic Assessment towards Improved Energy Management of a Thermal Power Plant: A Case Study. Sustainability, 15(6), 5452. https://doi.org/10.3390/su15065452
Vancouver
Maruf MH, July SA, Rabbani M, Sahrani S, Lipu MSH, Sarker MR, et al. Energy and Exergy-Based Efficiency, Sustainability and Economic Assessment towards Improved Energy Management of a Thermal Power Plant: A Case Study. Sustainability. 2023;15(6):5452. doi:10.3390/su15065452
BibTeX
@article{Maruf2023,
author = {Maruf, Md Hasan and July, Sameya Afrin and Rabbani, Mamun and Sahrani, Shafrida and Lipu, Molla Shahadat Hossain and Sarker, Mahidur R. and Ashique, Ratil H. and Kabir, Md. Shahrial and Shihavuddin, A. S. M.},
title = {Energy and Exergy-Based Efficiency, Sustainability and Economic Assessment towards Improved Energy Management of a Thermal Power Plant: A Case Study},
journal = {Sustainability},
year = {2023},
volume = {15},
number = {6},
pages = {5452},
doi = {10.3390/su15065452}
}