EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Transmission Network Loss Reduction and Voltage Profile Improvement Using Network Restructuring and Optimal DG Placement

Pramod Kumar, Nagendra Kumar Swarnkar, Ahmed Ali, Om Prakash Mahela, Baseem Khan, Divya Anand, Julien Brito Ballester

Sustainability · 05.01.2023 · 15 (2) · 976

DOI: 10.3390/su15020976 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sustainability, online erschienen am 05.01.2023. Verfasst von Pramod Kumar und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper introduced a method using hybrid combination of network restructuring and optimal placement of optimally sized distributed generators (DG) to reduce loss and improve voltage profile in a practical transmission network for scenario of high load demand for a period of ten years. A study is performed for four study cases which includes the test transmission network without considering optimal DG placement and network restructuring, considering network restructuring, optimal placement of DG units using proposed grid parameter oriented harmony search algorithm (GPOHSA) and considering hybrid combination of network restructuring and DG placement using GPOHSA. Network restructuring is achieved by addition of a new 400 kV Grid-substation (GSS) and a 220 kV GSS along with associated transmission system. GPOHSA is obtained by a modification in the conventional harmony search algorithm (HSA) where grid coordinates are used for locating the individuals in an objective space. Performance Improvement Indicators such as real power loss reduction indicator (SPLRI), reactive power loss reduction indicator (SQLRI) and summation of node voltage deviation reduction indicator (SNVDRI) are proposed to evaluate performance of each case of study. The period of investment return is assessed to evaluate the pay back period of the investments incurred in network restructuring and DG units. It is established that hybrid combination of network restructuring and DG units placement using GPOHSA is effective to meet the increased load demand for time period of ten years with reduced losses and improved voltage profile. Investment incurred on the network restructuring and DG units placement will be recovered in a time period of 4 years. Effectiveness of the GPOHSA is better relative to the conventional genetic algorithm (GA) for DG unit placement. The study is performed using the MATLAB software on a practical transmission network in India.

Zitieren

APA

Kumar, P., Swarnkar, N. K., Ali, A., Mahela, O. P., Khan, B., Anand, D., & Ballester, J. B. (2023). Transmission Network Loss Reduction and Voltage Profile Improvement Using Network Restructuring and Optimal DG Placement. Sustainability, 15(2), 976. https://doi.org/10.3390/su15020976

Vancouver

Kumar P, Swarnkar NK, Ali A, Mahela OP, Khan B, Anand D, et al. Transmission Network Loss Reduction and Voltage Profile Improvement Using Network Restructuring and Optimal DG Placement. Sustainability. 2023;15(2):976. doi:10.3390/su15020976

BibTeX
@article{Kumar2023,
  author = {Kumar, Pramod and Swarnkar, Nagendra Kumar and Ali, Ahmed and Mahela, Om Prakash and Khan, Baseem and Anand, Divya and Ballester, Julien Brito},
  title = {Transmission Network Loss Reduction and Voltage Profile Improvement Using Network Restructuring and Optimal DG Placement},
  journal = {Sustainability},
  year = {2023},
  volume = {15},
  number = {2},
  pages = {976},
  doi = {10.3390/su15020976}
}
Kostenlos starten →