EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

ISO 16000-8 and Ventilation Performance: A Critical Review

Sascha Nehr, Julia Hurraß

Standards · 20.04.2026 · 6 (2) · 16

DOI: 10.3390/standards6020016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Standards, online erschienen am 20.04.2026. Verfasst von Sascha Nehr und 1 weiteren Autor:innen. Die Arbeit nennt 112 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hochschule Düsseldorf University of Applied Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Standard 16000-8 of the International Organization for Standardization (ISO 16000-8) specifies the assessment of ventilation performance using age-of-air concepts and tracer gas techniques. Since its publication in 2007, ventilation systems and assessment practices have evolved considerably, driven by increased use of mixed-mode and decentralized ventilation and advances in modeling and measurement technologies. This review examines how ISO 16000-8 can be modernized to harmonize with adjacent ventilation and indoor air quality standards while remaining applicable to contemporary systems and emerging approaches. A structured literature search of Web of Science and Google Scholar identified 76 studies (2007–2026) that engage with ISO 16000-8, age-of-air metrics, or tracer gas-based assessment. The literature was synthesized qualitatively using the framework of Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA), classifying studies into performance assessment, measurement–simulation convergence, and standardization discourse. The synthesis shows that while the conceptual foundations of ISO 16000-8 remain valid, assumptions of homogeneous mixing and steady-state conditions are often violated in real buildings, leading to inconsistent application of age-of-air indicators. Field and laboratory studies under point-source conditions demonstrate reduced ventilation effectiveness of 0.73–0.82 in classrooms and 0.5–1.4 in various indoor environments, instead of ≈1 for perfect mixing. Spatial heterogeneity is also observed in mixed-mode systems, with an efficiency around 0.5. In decentralized and façade-integrated systems, air exchange effectiveness deviates from theoretical expectations, indicating inhomogeneous air renewal and short-circuiting. Field measurements show configuration-dependent discrepancies in air exchange rates (e.g., carbon dioxide vs. perfluorocarbon tracer methods under varying door positions), while wind induces time-varying infiltration. Collectively, the literature demonstrates systematic violations of well-mixed and steady-state assumptions underpinning ISO 16000-8. Fragmentation between ventilation performance standards and indoor air quality regulation limits practical uptake. Emerging experimental, numerical, and data-driven methods complement ISO 16000-8, provided applicability domains and uncertainties are addressed. The review concludes that ISO 16000-8 should be modernized toward a harmonized, performance-based framework integrating diverse ventilation systems and assessment technologies.

Förderung

  • Hochschule Düsseldorf University of Applied Sciences

Zitieren

APA

Nehr, S., & Hurraß, J. (2026). ISO 16000-8 and Ventilation Performance: A Critical Review. Standards, 6(2), 16. https://doi.org/10.3390/standards6020016

Vancouver

Nehr S, Hurraß J. ISO 16000-8 and Ventilation Performance: A Critical Review. Standards. 2026;6(2):16. doi:10.3390/standards6020016

BibTeX
@article{Nehr2026,
  author = {Nehr, Sascha and Hurraß, Julia},
  title = {ISO 16000-8 and Ventilation Performance: A Critical Review},
  journal = {Standards},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {16},
  doi = {10.3390/standards6020016}
}
Kostenlos starten →