EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of Shape-Dependent Internal Blast Responses of Enclosed Circular and Square Reinforced Concrete Structures Under Progressive Charge Weight Conditions Using Finite Element Analysis

Hwan Jung, Jang-Ho Jay Kim

Solids · 10.08.2026 · 7 (4) · 38

DOI: 10.3390/solids7040038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Solids, online erschienen am 10.08.2026. Verfasst von Hwan Jung und 1 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Foundation Of Nuclear Safety.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Enclosed reinforced concrete structures subjected to internal blast loading represent a critical safety concern in infrastructure applications where detonations may occur within confined spaces. Although circular cross-sections have been widely adopted for blast-resistant containment structures, systematic quantitative comparisons of internal blast responses between circular and square enclosed configurations under progressive charge weight conditions remain limited. LS-DYNA finite element simulations are conducted under four trinitrotoluene (TNT) charge weight conditions ranging from 1200 to 2500 kg, and the failure-inducing blast load is defined as the minimum charge weight at which continuous concrete element deletion first occurs in the roof or side-wall region. In this study, the failure-inducing blast load is interpreted as an erosion-based comparative indicator under the adopted empirical blast-loading framework rather than as an absolute real-world confined-blast failure threshold. The roof failure-inducing blast load is identical for both structures at 1200 kg, whereas the side-wall failure-inducing blast loads are 2500 kg for the circular structure and 1500 kg for the square structure, indicating approximately 67% higher side-wall blast resistance in the circular structure. This difference is attributed to the membrane action of the curved wall, which redistributes internal blast-induced lateral pressure along the circumferential direction and limits out-of-plane deformation. Under the 2500-kg condition, the peak side-wall displacement of the square structure is 161.6% higher than that of the circular structure, whereas its peak roof displacement is 33.3% lower. Axial strains at all reinforcement locations remain within the elastic range, confirming that concrete damage is governed by the low tensile capacity of concrete rather than reinforcement yielding.

Förderung

  • Korea Foundation Of Nuclear Safety

Zitieren

APA

Jung, H., & Kim, J. J. (2026). Comparison of Shape-Dependent Internal Blast Responses of Enclosed Circular and Square Reinforced Concrete Structures Under Progressive Charge Weight Conditions Using Finite Element Analysis. Solids, 7(4), 38. https://doi.org/10.3390/solids7040038

Vancouver

Jung H, Kim JJ. Comparison of Shape-Dependent Internal Blast Responses of Enclosed Circular and Square Reinforced Concrete Structures Under Progressive Charge Weight Conditions Using Finite Element Analysis. Solids. 2026;7(4):38. doi:10.3390/solids7040038

BibTeX
@article{Jung2026,
  author = {Jung, Hwan and Kim, Jang-Ho Jay},
  title = {Comparison of Shape-Dependent Internal Blast Responses of Enclosed Circular and Square Reinforced Concrete Structures Under Progressive Charge Weight Conditions Using Finite Element Analysis},
  journal = {Solids},
  year = {2026},
  volume = {7},
  number = {4},
  pages = {38},
  doi = {10.3390/solids7040038}
}
Kostenlos starten →