Understanding and Mitigating Corona Quenching in ESPs Under High Fly Ash Concentrations in a 660 MW Coal-Fired Unit
Separations · 08.02.2026 · 13 (2) · 60
DOI: 10.3390/separations13020060 ↗Kurz gefasst
Fachartikel in der Zeitschrift Separations, online erschienen am 08.02.2026. Verfasst von Haibao Zhao und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Plan, Development Plan for Youth Innovation Teams in Higher Education Institutions of Shandong Province.
Abstract (Originalsprache)
Corona quenching is a major obstacle to the stable and efficient operation of electrostatic precipitators (ESPs) in coal-fired power plants, particularly under high-ash coal combustion. This study evaluates a novel double-V labyrinth pre-collection device as an active strategy to mitigate corona quenching. Field measurements from a 660 MW ultra-supercritical coal-fired unit, combined with computational fluid dynamics (CFD) simulations, demonstrate that the retrofit significantly improved inlet flow uniformity and reduced fly ash concentration before the ESP. Consequently, corona discharge stability was enhanced, overall collection efficiency increased from 99.42% to 99.92%, and outlet fly ash concentration decreased from 81 mg/m3 to 20.5 mg/m3. Although the pressure drop rose modestly (128 Pa to 187.5 Pa), the overall ESP energy demand was reduced due to more stable operation at lower voltages. These results confirm the technical feasibility and engineering applicability of pre-collection technology, providing a cost-effective solution to overcome corona quenching and ensure ultra-low emission compliance in large coal-fired units.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Plan
- Development Plan for Youth Innovation Teams in Higher Education Institutions of Shandong Province
- Shandong SMEs Innovation Capability Enhancement Project
Zitieren
APA
Zhao, H., Li, P., Liu, H., Liu, T., & Yang, Z. (2026). Understanding and Mitigating Corona Quenching in ESPs Under High Fly Ash Concentrations in a 660 MW Coal-Fired Unit. Separations, 13(2), 60. https://doi.org/10.3390/separations13020060
Vancouver
Zhao H, Li P, Liu H, Liu T, Yang Z. Understanding and Mitigating Corona Quenching in ESPs Under High Fly Ash Concentrations in a 660 MW Coal-Fired Unit. Separations. 2026;13(2):60. doi:10.3390/separations13020060
BibTeX
@article{Zhao2026,
author = {Zhao, Haibao and Li, Peiyuan and Liu, Hanxiao and Liu, Tao and Yang, Zhengda},
title = {Understanding and Mitigating Corona Quenching in ESPs Under High Fly Ash Concentrations in a 660 MW Coal-Fired Unit},
journal = {Separations},
year = {2026},
volume = {13},
number = {2},
pages = {60},
doi = {10.3390/separations13020060}
}
EUVIMED