EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization and Validation of Sensitive UPLC-PDA Method for Simultaneous Determination of Thymoquinone and Glibenclamide in SNEDDs Formulations Using Response Surface Methodology

Doaa Hasan Alshora, Mohamed Abbas Ibrahim, Abdelrahman Y. Sherif

Separations · 19.11.2023 · 10 (11) · 577

DOI: 10.3390/separations10110577 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Separations, online erschienen am 19.11.2023. Verfasst von Doaa Hasan Alshora und 2 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deputyship for Research & Innovation, Ministry of Education in Saudi Arabia.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of analytical procedures capable of simultaneous determination of two or more drugs is in crucial demand due to the availability of different formulations that are composed of different APIs. The presented study aimed to optimize and validate a simple, accurate, and sensitive UPLC analytical method for the simultaneous determination of thymoquinone (TQ) and Glibenclamide (GB) using response surface methodology, and apply this method in pharmaceutical formulations. A 32 full design of experiment was utilized to study the impacts of the independent parameters (acetonitrile ACN concentration, A; and column temperature, B) on the drugs’ analytical attributes (viz, retention time, peak area, and peak asymmetry, in addition to the resolution between TQ and GB peaks). The results revealed that the independent parameters exhibited highly significant (p < 0.05) antagonistic effects on retention times for TQ and GB peaks, in addition to the agnostic effect on GB peak symmetry (p-value = 0.001). Moreover, antagonistic impacts (p < 0.05) on the resolution between TQ and GB peaks were found for both independent factors (A and B). The statistical software suggested 46.86% of ACN (A) and 38.80 °C for column temperature (B) for optimum analytical responses. The optimized green method was discovered to be acceptable in terms of selectivity, precision, accuracy, robustness, sensitivity, and specificity. Moreover, the optimized simultaneous method was successfully able to determine the contents of TQ and GB in self-nanoemulsifying drug delivery (SNEDD) formulation, in which the results showed that GB and TQ content within the prepared formulations were 1.54 ± 0.023 and 3.62 ± 0.031 mg/gm, respectively. In conclusion, the developed assay was efficient and valid in analyzing TQ and GB simultaneously in bulk and self-nanoemulsifying drug delivery system (SNEDDs) formulations.

Förderung

  • Deputyship for Research &amp; Innovation, Ministry of Education in Saudi Arabia

Zitieren

APA

Alshora, D. H., Ibrahim, M. A., & Sherif, A. Y. (2023). Optimization and Validation of Sensitive UPLC-PDA Method for Simultaneous Determination of Thymoquinone and Glibenclamide in SNEDDs Formulations Using Response Surface Methodology. Separations, 10(11), 577. https://doi.org/10.3390/separations10110577

Vancouver

Alshora DH, Ibrahim MA, Sherif AY. Optimization and Validation of Sensitive UPLC-PDA Method for Simultaneous Determination of Thymoquinone and Glibenclamide in SNEDDs Formulations Using Response Surface Methodology. Separations. 2023;10(11):577. doi:10.3390/separations10110577

BibTeX
@article{Alshora2023,
  author = {Alshora, Doaa Hasan and Ibrahim, Mohamed Abbas and Sherif, Abdelrahman Y.},
  title = {Optimization and Validation of Sensitive UPLC-PDA Method for Simultaneous Determination of Thymoquinone and Glibenclamide in SNEDDs Formulations Using Response Surface Methodology},
  journal = {Separations},
  year = {2023},
  volume = {10},
  number = {11},
  pages = {577},
  doi = {10.3390/separations10110577}
}
Kostenlos starten →