EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rilpivirine and Dolutegravir Simultaneously Measured via RP-HPLC-PDA with Box–Behnken Design Application: A Study of Forced Degradation under Various Conditions

Shadma Wahab, Mohammad Khalid, Sarfaraz Ahmad, Sherouk Hussein Sweilam

Separations · 08.03.2023 · 10 (3) · 185

DOI: 10.3390/separations10030185 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Separations, online erschienen am 08.03.2023. Verfasst von Shadma Wahab und 3 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Prince Sattam Bin Abdulaziz University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Simultaneous estimation of rilpivirine (RLVN) and dolutegravir (DTGR) in bulk and tablet dosage forms via RP-HPLC-PDA with a Box–Behnken design (BBD) has been performed in this study to develop a fast, precise, timely and cost-saving method for estimating RLVN and DTGR in bulk and tablet dosage forms. The chromatographic conditions were optimized via the BBD, and the developed method was validated according to the ICH guidelines. Additionally, forced degradation studies were also conducted. RLVN and DTGR peaks were observed at retention times of 2.167 and 2.716 min, respectively, in a 6-min runtime. Kromasil 150 mm× 4.6 mm, 5 µm C 18 column was used. The flow rate of the mobile phase was 1.0 mL/min at a temperature of 30 °C. The mobile phase composition was a 0.1% OPA buffer and acetonitrile (ACN) in a 60:40 ratio. Elutes were measured at 260 nm (max) after being injected in a sample volume of 10 µL. The assay result of the marketed tablet was 99.19% and 99.09% for RLVN and DTGR, respectively. The results of forced degradation studies in different chemical environments conditions such as acid, base, dry heat, photo-stability, neutral, and oxidation conditions were observed for RLVN (5.96, 4.79, 3.27, 2.36, 0.99, and 4.35 in percentage degradation) and DTGR (5.67, 4.44, 4.09, 1.81, 0.43, and 4.28 in percentage degradation). The results of the validation parameters were within an acceptable range. The newly formed RP-HPLC-PDA method is novel, fast, precise, time-saving, and cost-effective.

Förderung

  • Prince Sattam Bin Abdulaziz University

Zitieren

APA

Wahab, S., Khalid, M., Ahmad, S., & Sweilam, S. H. (2023). Rilpivirine and Dolutegravir Simultaneously Measured via RP-HPLC-PDA with Box–Behnken Design Application: A Study of Forced Degradation under Various Conditions. Separations, 10(3), 185. https://doi.org/10.3390/separations10030185

Vancouver

Wahab S, Khalid M, Ahmad S, Sweilam SH. Rilpivirine and Dolutegravir Simultaneously Measured via RP-HPLC-PDA with Box–Behnken Design Application: A Study of Forced Degradation under Various Conditions. Separations. 2023;10(3):185. doi:10.3390/separations10030185

BibTeX
@article{Wahab2023,
  author = {Wahab, Shadma and Khalid, Mohammad and Ahmad, Sarfaraz and Sweilam, Sherouk Hussein},
  title = {Rilpivirine and Dolutegravir Simultaneously Measured via RP-HPLC-PDA with Box–Behnken Design Application: A Study of Forced Degradation under Various Conditions},
  journal = {Separations},
  year = {2023},
  volume = {10},
  number = {3},
  pages = {185},
  doi = {10.3390/separations10030185}
}
Kostenlos starten →