EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of the Compaction Simulator to Industrial Tablet Press Transferability for a Fixed-Dose Combination Immediate-Release Formulation

Tibor Casian, Ioan Tomuță, Béla Kovács, Elena-Camelia Norocel, Sonia Iurian, Alexandru Găvan, Alina Porfire, Răzvan Cherecheș, Alexandru Oprea, Marcela Achim

Scientia Pharmaceutica · 16.11.2026 · 94 (4) · 114

DOI: 10.3390/scipharm94040114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Scientia Pharmaceutica, online erschienen am 16.11.2026. Verfasst von Tibor Casian und 9 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Romanian National Authority for Scientific Research and Innovation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Compaction simulators are widely used to reduce material consumption during process development, but the conditions under which simulator-derived data reliably predict industrial rotary press performance remain incompletely understood for multi-component, viscoelastic formulations. This study evaluated agreement between a Styl’One Nano compaction simulator and a 32-station industrial rotary press (PharmaLand PTP-32) for a fixed-dose combination of ibuprofen, paracetamol, and caffeine, using a matched Box–Behnken design executed in parallel on both instruments via equivalent dwell times. Agreement across four critical quality attributes (tensile strength, mass variability, friability, and disintegration time) was assessed via design of experiments (DoE) coefficient analysis and Bland–Altman comparison. Punch displacement profiling revealed peak velocity ratios of 2.4–3.9 (simulator/press) despite matched dwell times, and strain rate sensitivity testing confirmed that this kinematic mismatch underlies the observed divergence. Because the two instruments used punches of different compression area, a response surface analysis was performed on a common compaction-pressure basis. The divergence in tensile strength and friability persisted after removal of this geometric confound, confirming that it reflects genuine differences in compaction behavior. Convergence followed a trade-off boundary rather than a simple threshold: the pre-compression pressure required for statistical equivalence fell from 21.3 to 9.4 MPa as main compression pressure rose from 130 to 182 MPa, while at 120 MPa no pre-compression level achieved agreement. These findings show that simulator-to-press transferability is CQA- and process-window-specific.

Förderung

  • Romanian National Authority for Scientific Research and Innovation

Zitieren

APA

Casian, T., Tomuță, I., Kovács, B., Norocel, E., Iurian, S., Găvan, A., Porfire, A., Cherecheș, R., Oprea, A., & Achim, M. (2026). Evaluation of the Compaction Simulator to Industrial Tablet Press Transferability for a Fixed-Dose Combination Immediate-Release Formulation. Scientia Pharmaceutica, 94(4), 114. https://doi.org/10.3390/scipharm94040114

Vancouver

Casian T, Tomuță I, Kovács B, Norocel E, Iurian S, Găvan A, et al. Evaluation of the Compaction Simulator to Industrial Tablet Press Transferability for a Fixed-Dose Combination Immediate-Release Formulation. Scientia Pharmaceutica. 2026;94(4):114. doi:10.3390/scipharm94040114

BibTeX
@article{Casian2026,
  author = {Casian, Tibor and Tomuță, Ioan and Kovács, Béla and Norocel, Elena-Camelia and Iurian, Sonia and Găvan, Alexandru and Porfire, Alina and Cherecheș, Răzvan and Oprea, Alexandru and Achim, Marcela},
  title = {Evaluation of the Compaction Simulator to Industrial Tablet Press Transferability for a Fixed-Dose Combination Immediate-Release Formulation},
  journal = {Scientia Pharmaceutica},
  year = {2026},
  volume = {94},
  number = {4},
  pages = {114},
  doi = {10.3390/scipharm94040114}
}
Kostenlos starten →