EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Characterization of the Sensitivity and Survey Potential of a Commercial Metal Detector Mounted on a Robotic Platform for Safely Detecting Plastic Landmines

Fronefield Crawford, Timothy Bechtel, Lorenzo Capineri, Gennadiy Pochanin, Seth Kauffman, Frankie Delgado, Tyler Howe

Sensors · 19.11.2026 · 26 (22) · 7310

DOI: 10.3390/s26227310 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.11.2026. Verfasst von Fronefield Crawford und 6 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NATO Science for Peace and Security Programme.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The widespread presence of landmines and unexploded ordnance in the Ukraine conflict zone has created an urgent need for reliable sensing technologies capable of supporting autonomous and semi-autonomous humanitarian demining. As part of a multi-sensor approach, metal detectors (MDs) remain one of the primary sensors for locating buried explosive hazards. In this work we present an experimental characterization of the CEIA MIL-D1 MD using inert mine simulants of four common types of plastic landmines encountered in the Ukraine conflict zone (the PFM-1 “butterfly” mine, PTM-1G “stick” anti-tank (AT) mine, the TM-62P3 AT mine, and the PMN-4 mine). We investigated the MD efficacy in a configuration in which the coil was mounted at a fixed height and offset from a robotic platform being operated remotely, a configuration which is safer for the operator than the standard use of the MD with lateral sweeping by hand. We conducted controlled laboratory experiments to measure the MD’s two-dimensional detection footprint as a function of sensor (coil) height and lateral offset from the coil center. We produced quantitative detection regions for each target, which informs how well we can detect these targets in an idealized situation. Our measurements were complemented by field experiments in a realistic test lane containing these same mine simulants along with representative metallic clutter objects. At our nominal MD operating height of 11 cm, the detector reliably detected 3 of the 4 investigated mine simulants in the test lane. The PFM-1 mine was only sporadically detected, but this surface mine can be detected visually via cameras and automated object recognition. Our results indicate that maintaining a target distance within approximately 10 cm of the centerline of the MD coil provides high-confidence detections, suggesting a conservative survey lane width of 20 cm, while a 30 cm lane width may be acceptable under similar field conditions. This study establishes a quantitative performance baseline for the CEIA MIL-D1 MD undergoing linear motion in a fixed mounted configuration, and constrains lane-planning parameters and ground survey efficiency for our multisensor humanitarian demining system.

Förderung

  • NATO Science for Peace and Security Programme

Zitieren

APA

Crawford, F., Bechtel, T., Capineri, L., Pochanin, G., Kauffman, S., Delgado, F., & Howe, T. (2026). Characterization of the Sensitivity and Survey Potential of a Commercial Metal Detector Mounted on a Robotic Platform for Safely Detecting Plastic Landmines. Sensors, 26(22), 7310. https://doi.org/10.3390/s26227310

Vancouver

Crawford F, Bechtel T, Capineri L, Pochanin G, Kauffman S, Delgado F, et al. Characterization of the Sensitivity and Survey Potential of a Commercial Metal Detector Mounted on a Robotic Platform for Safely Detecting Plastic Landmines. Sensors. 2026;26(22):7310. doi:10.3390/s26227310

BibTeX
@article{Crawford2026,
  author = {Crawford, Fronefield and Bechtel, Timothy and Capineri, Lorenzo and Pochanin, Gennadiy and Kauffman, Seth and Delgado, Frankie and Howe, Tyler},
  title = {Characterization of the Sensitivity and Survey Potential of a Commercial Metal Detector Mounted on a Robotic Platform for Safely Detecting Plastic Landmines},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {22},
  pages = {7310},
  doi = {10.3390/s26227310}
}
Kostenlos starten →