Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T
Sensors · 19.11.2026 · 26 (22) · 7302
DOI: 10.3390/s26227302 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 19.11.2026. Verfasst von Akbar Alipour und 8 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Superparamagnetic iron oxide nanoparticles (SPION) are widely used as MRI contrast agents for cell tracking and molecular imaging. However, their detection using conventional T2/T2* weighted and susceptibility-weighted MRI relies on negative contrast (signal voids), which lacks specificity because similar hypointense signals can arise from other sources of magnetic susceptibility. This study introduces Frequency Shift Imaging (FSI), a positive-contrast technique based on an adiabatic Shinnar-Le Roux (SLR) self-refocused pulse that addresses the limited specificity of conventional SPION imaging.
Methods
An adiabatic self-refocused RF pulse was designed using the SLR algorithm for frequency-selective positive-contrast imaging. The optimized pulse had a spectral bandwidth of 370 Hz, a peak RF amplitude of 13 μT, and a duration of 15 ms. FSI data were acquired on a 7T MRI scanner. Phantom experiments used agarose-embedded 30 nm cell-labeled SPION at 0%, 25%, 75%, and 100% concentrations (pure). In vivo validation was performed following intramuscular SPION injection into the hind limb of a mouse. FSI images were compared with conventional acquisitions.
Results
Quantitative phantom analysis showed normalized FSI signal intensities of 25.02% and 75.16% for samples containing 25% and 75% labeled cells, respectively, demonstrating an approximately proportional relationship between FSI signal and labeled-cell concentration. In vivo, FSI generated localized hyperintense positive contrast at the SPION injection site, providing improved conspicuity compared with the corresponding negative-contrast signal void. Discussion and Conclusion: FSI enables frequency-selective positive-contrast SPION imaging at 7T with improved robustness to B1 variations and a shorter calculated minimum echo time compared with the corresponding separate pulse-pair configuration. The self-refocused design may also offer potential advantages in RF power deposition, although SAR reduction remains to be quantitatively evaluated.
Zitieren
APA
Alipour, A., Chiu, M., Alper, J., Dyvorne, H., Verma, G., Rashid, S., Teunissen, A. J. P., Fayad, Z. A., & Balchandani, P. (2026). Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T. Sensors, 26(22), 7302. https://doi.org/10.3390/s26227302
Vancouver
Alipour A, Chiu M, Alper J, Dyvorne H, Verma G, Rashid S, et al. Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T. Sensors. 2026;26(22):7302. doi:10.3390/s26227302
BibTeX
@article{Alipour2026,
author = {Alipour, Akbar and Chiu, Madison and Alper, Judy and Dyvorne, Hadrien and Verma, Gaurav and Rashid, Shams and Teunissen, Abraham J. P. and Fayad, Zahi A. and Balchandani, Priti},
title = {Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T},
journal = {Sensors},
year = {2026},
volume = {26},
number = {22},
pages = {7302},
doi = {10.3390/s26227302}
}
EUVIMED