EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Machine Learning Field Calibration of a Low-Cost Carbon Nanotube Sensor Array Utilizing Near-Road Ambient Ozone Measurements

Gautam Naishadham, Elena Bekyarova, Krishna Naishadham

Sensors · 19.11.2026 · 26 (22) · 7301

DOI: 10.3390/s26227301 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.11.2026. Verfasst von Gautam Naishadham und 2 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institutes of Health.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time monitoring of environmental pollutants, such as ozone and particulate matter, using low-cost sensors, has become increasingly important in various fields, including wearable devices, public health and occupational safety. Nanotechnology-based sensors offer significant advantages over commercial metal oxide semiconductor and electrochemical sensors, including low-temperature operation, low power consumption, enhanced sensitivity, and chemical functionalization of nanomaterials for selective gas detection. In this study, we integrate carbon nanotube (CNT) sensors based on thin films of three novel functionalized nanomaterials into a compact five-element sensor array and conduct ambient ozone measurements at a near-road location in downtown Atlanta, an area characterized by high vehicular emissions. Three distinct ozone-sensitive functionalized CNTs are investigated, namely, (a) Pt-CNT, comprising pristine CNTs decorated with platinum nanoparticles (~2 nm in diameter); (b) PBD-CNT, a composite of pristine CNTs and polybutadiene (PBD); and (c) ODA-CNT, comprising pristine CNTs covalently modified with octadecylamine (ODA) functional groups. The ambient measurements are performed during summer when the ozone levels are high due to abundant sunshine and high concentrations of precursor pollutants emitted by vehicular traffic. The field data comprising impedance magnitude and phase responses of the five sensors are analyzed using machine learning regression employing ensembles of gradient-boosted and random forest decision trees with blocked cross-validation. The sensor array is collocated with a precision ozone monitor, which provides the reference ambient ozone concentrations to calibrate the CNT sensor elements. Prediction on an unseen data block (not used in training and cross-validation) reveals that the array discriminates ambient ozone levels above 20 ppb with RMSE < 4 ppb, and R2 = 0.9.

Förderung

  • National Institutes of Health

Zitieren

APA

Naishadham, G., Bekyarova, E., & Naishadham, K. (2026). Machine Learning Field Calibration of a Low-Cost Carbon Nanotube Sensor Array Utilizing Near-Road Ambient Ozone Measurements. Sensors, 26(22), 7301. https://doi.org/10.3390/s26227301

Vancouver

Naishadham G, Bekyarova E, Naishadham K. Machine Learning Field Calibration of a Low-Cost Carbon Nanotube Sensor Array Utilizing Near-Road Ambient Ozone Measurements. Sensors. 2026;26(22):7301. doi:10.3390/s26227301

BibTeX
@article{Naishadham2026,
  author = {Naishadham, Gautam and Bekyarova, Elena and Naishadham, Krishna},
  title = {Machine Learning Field Calibration of a Low-Cost Carbon Nanotube Sensor Array Utilizing Near-Road Ambient Ozone Measurements},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {22},
  pages = {7301},
  doi = {10.3390/s26227301}
}