Abstract (Originalsprache)

In total knee arthroplasty (TKA), intraoperative soft-tissue balance and joint gap accuracy directly affect postoperative joint stability, functional recovery and long-term implant survivorship, but current clinical practice still lacks stable, quantitative measurement tools with sufficient precision. This study developed an integrated knee distractor with integrated force feedback and gap detection; the hardware design reserves two independent actuation channels, whereas all experiments reported in this study were conducted in single-channel mode. A mechanism-informed nonlinear error compensation method was proposed to reduce load-dependent gap-measurement error. First, the load-bearing structure was abstracted as a Γ-shaped cantilever beam model under small-deformation and linear-elastic assumptions, and mechanical analysis was conducted to clarify the formation mechanism of gap measurement error induced by load-induced structural deformation and assembly inaccuracies. Guided by this mechanistic analysis, a dual-input BP neural network was constructed with displacement-sensor output and measured force as inputs and the actual distraction gap as output; the mechanical model informed the selection of these two inputs (mechanism-informed input selection) rather than imposing deformation equations as training constraints. The model was trained and evaluated using 200 averaged calibration samples, constructed from a structured grid of 40 displacement settings (0.5–20 mm at 0.5 mm intervals) crossed with five nominal force levels (20, 40, 60, 80, and 100 N), split at the averaged-sample level into 140 training, 20 validation, and 40 test samples. On the independent test set, the proposed method achieved a root mean square error (RMSE) of 0.1123 mm, a mean absolute error (MAE) of 0.0893 mm, and a maximum absolute error (MaxAE) of 0.3189 mm, with all 40 test samples having absolute errors below the predefined engineering accuracy target of ±0.5 mm under the specified bench-top conditions. This study provides a promising engineering approach for reducing load-dependent gap-measurement error under controlled bench-top conditions; validation on anatomically and biomechanically realistic systems is required before any claim of intraoperative suitability.

Förderung

  • Jilin Province Science and Technology Development Plan

Zitieren

APA

Zhang, E., Xu, H., Chen, G., Liu, X., Hu, J., Ju, M., & Han, T. (2026). Γ-Cantilever Mechanism-Informed BP Neural Network Compensation for Gap Measurement of an Integrated Knee Distractor in Total Knee Arthroplasty. Sensors, 26(22), 7169. https://doi.org/10.3390/s26227169

Vancouver

Zhang E, Xu H, Chen G, Liu X, Hu J, Ju M, et al. Γ-Cantilever Mechanism-Informed BP Neural Network Compensation for Gap Measurement of an Integrated Knee Distractor in Total Knee Arthroplasty. Sensors. 2026;26(22):7169. doi:10.3390/s26227169

BibTeX
@article{Zhang2026,
  author = {Zhang, Enkui and Xu, He and Chen, Guanyu and Liu, Xuan and Hu, Jun and Ju, Mingchi and Han, Tailin},
  title = {Γ-Cantilever Mechanism-Informed BP Neural Network Compensation for Gap Measurement of an Integrated Knee Distractor in Total Knee Arthroplasty},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {22},
  pages = {7169},
  doi = {10.3390/s26227169}
}
Kostenlos starten →