A Functional-Integrated Knee Device for Distal Perception and Energy Harvesting in Phase-Synchronized Hip Exoskeleton Control
Sensors · 12.11.2026 · 26 (22) · 7145
DOI: 10.3390/s26227145 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 12.11.2026. Verfasst von Xinrui Wang und 6 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Self-Planned Task of State Key Laboratory of Robotics and Systems, PhD Candidate Innovation Fund of State Key Laboratory of Robotics and Systems, National Natural Science Foundation of China.
Abstract (Originalsprache)
Lightweight hip exoskeletons typically rely on proximal sensing, which limits access to distal lower-limb kinematics and may compromise gait phase synchronization during dynamic locomotion. Adding dedicated distal encoders can improve perception but increases system mass, wiring complexity, and power consumption. To address this trade-off, this paper presents a functionally integrated knee device that combines passive magnetic-strain motion sensing with mechanical energy harvesting to provide knee kinematic information for hip exoskeleton gait phase estimation and explore harvested-energy supply for the local sensing node. The knee device employs a unidirectional pawl-ratchet planetary transmission to harvest mechanical energy during knee extension, achieving an electrical power output of up to 0.378 W. Meanwhile, a passive magnetic-strain sensing array converts knee rotation into high-frequency electrical signals without active electromagnetic excitation. A dual-head 1D-CNN-LSTM network is developed to simultaneously classify locomotion modes and reconstruct continuous knee joint trajectories from 1000 Hz strain signals. The network achieves an overall locomotion classification accuracy of 99.72%, with a trajectory reconstruction MAE of 3.2989°, RMSE of 4.1664°, and R2 of 0.9801 on the independent test dataset covering level walking and running at speeds of 1–4 m/s and stair ascent. The reconstructed knee kinematics are further fused with hip motor encoder feedback to drive a speed-adaptive finite state machine for real-time stance/swing phase estimation. Compared with plantar-pressure-based reference events, the mean phase switching errors remain within 0.36% of the gait cycle for swing-to-stance transitions and 2.07% of the gait cycle for stance-to-swing transitions across locomotion speeds of 1–4 m/s. The observed phase advance at the stance-to-swing transition also indicates the potential of the proposed timing strategy to compensate for actuator response latency. These results demonstrate that functionally integrating passive distal perception with energy harvesting can provide reliable kinematic information for phase-synchronized hip exoskeleton control while reducing the need for dedicated distal sensing hardware.
Förderung
- Self-Planned Task of State Key Laboratory of Robotics and Systems
- PhD Candidate Innovation Fund of State Key Laboratory of Robotics and Systems
- National Natural Science Foundation of China
Zitieren
APA
Wang, X., Dong, W., Wang, W., Lin, W., Cong, M., Gao, Y., & Dong, H. (2026). A Functional-Integrated Knee Device for Distal Perception and Energy Harvesting in Phase-Synchronized Hip Exoskeleton Control. Sensors, 26(22), 7145. https://doi.org/10.3390/s26227145
Vancouver
Wang X, Dong W, Wang W, Lin W, Cong M, Gao Y, et al. A Functional-Integrated Knee Device for Distal Perception and Energy Harvesting in Phase-Synchronized Hip Exoskeleton Control. Sensors. 2026;26(22):7145. doi:10.3390/s26227145
BibTeX
@article{Wang2026,
author = {Wang, Xinrui and Dong, Wei and Wang, Wenda and Lin, Weiqi and Cong, Moyue and Gao, Yongzhuo and Dong, Hui},
title = {A Functional-Integrated Knee Device for Distal Perception and Energy Harvesting in Phase-Synchronized Hip Exoskeleton Control},
journal = {Sensors},
year = {2026},
volume = {26},
number = {22},
pages = {7145},
doi = {10.3390/s26227145}
}
EUVIMED