Accelerometer- and Gyroscope-Based Sensor System for Detecting Swallowing, Speaking, and Coughing Events in ICU Patients
Sensors · 09.11.2026 · 26 (21) · 7089
DOI: 10.3390/s26217089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 09.11.2026. Verfasst von Constantijn Coppers und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Information Systems-IBiTech, Ghent University, Korneel Heymanslaan, 9000 Ghent, Belgium. Hauptthemen laut MEDLINE: Cough, Deglutition, Accelerometry, Speech. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Intensivpflege
Abstract (Originalsprache)
(1)
Background
Swallowing, coughing, and speaking are clinically relevant physiological events, but they are not routinely and continuously monitored in intensive care. This study evaluates the feasibility of detecting these events using inertial measurement unit (IMU) signals acquired from the cricoid and thoracic regions. (2)
Methods
Data were collected from 29 patients in the intensive care unit (ICU) during predefined swallowing, coughing, speaking, and movement tasks. A classical machine learning pipeline was developed and evaluated using leave-one-patient-out cross-validation. (3)
Results
Cricoid and thoracic accelerometer signals were informative for event detection, with the thoracic sensor particularly contributing to cough detection. Speaking (F1=0.80), coughing (F1=0.72), and aggregated swallowing (F1=0.74) were detected in this controlled experimental setting. (4)
Conclusions
The results support the feasibility of IMU-based detection of prompted swallowing, coughing, and speaking events in ICU patients. Further validation under spontaneous and clinically heterogeneous conditions is required before continuous clinical monitoring can be assessed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics and Information Systems-IBiTech, Ghent University, Korneel Heymanslaan, 9000 Ghent, Belgium.
- Partnership of Anesthesia, vzw Maria Middelares, Buitenring Sint-Denijs 30, 9000 Ghent, Belgium.
- Department CTO, vzw Maria Middelares, Buitenring Sint-Denijs 30, 9000 Ghent, Belgium.
- IDLab, Department of Electronics and Information Systems, Ghent University-Imec, Technologiepark-Zwijnaarde 122, 9052 Zwijnaarde, Belgium.
ORCID-Profile: Stijn Van de Velde, Guylian Stevens, Jonas Van Der Donckt, Marija Stojchevska, Sofie Van Hoecke, Pascal Verdonck
Zitieren
APA
Coppers, C., Velde, S. V., Stevens, G., Donckt, J. V., Stojchevska, M., Van Hoecke, S., & Verdonck, P. (2026). Accelerometer- and Gyroscope-Based Sensor System for Detecting Swallowing, Speaking, and Coughing Events in ICU Patients. Sensors, 26(21), 7089. https://doi.org/10.3390/s26217089
Vancouver
Coppers C, Velde SV, Stevens G, Donckt JV, Stojchevska M, Van Hoecke S, et al. Accelerometer- and Gyroscope-Based Sensor System for Detecting Swallowing, Speaking, and Coughing Events in ICU Patients. Sensors. 2026;26(21):7089. doi:10.3390/s26217089
BibTeX
@article{Coppers2026,
author = {Coppers, Constantijn and Velde, Stijn Van de and Stevens, Guylian and Donckt, Jonas Van Der and Stojchevska, Marija and Van Hoecke, Sofie and Verdonck, Pascal},
title = {Accelerometer- and Gyroscope-Based Sensor System for Detecting Swallowing, Speaking, and Coughing Events in ICU Patients},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {7089},
doi = {10.3390/s26217089}
}
EUVIMED