EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

External Magnetization-Based Elasto-Magnetic Sensing for Tension-Change Estimation in Prestressed Concrete Tendons

Sehwan Park, Junkyeong Kim, Minkyo Youm, Seunghee Park iD

Sensors · 07.11.2026 · 26 (21) · 7048

DOI: 10.3390/s26217048 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.11.2026. Verfasst von Sehwan Park und 3 weiteren Autor:innen. Beteiligte Einrichtung: AI Urban Disaster Prevention Research Center, Advanced Institute of Convergence Technology (AICT), Suwon 16229, Republic of Korea. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of the Interior and Safety, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Residual tension in tendons embedded in prestressed concrete girders cannot be measured with conventional elasto-magnetic sensors, because those sensors encircle the strand and must be installed before casting. This article evaluates a system that magnetizes an embedded tendon from outside the member and estimates the change in its total anchorage force from the local flux density. Three ferrite-core solenoids of 100, 200 and 300 mm outer diameter are placed on a common axis within a 300 mm envelope, and a board carrying 25 Hall and six temperature elements sits between the magnetizer and the concrete surface. Tests used one 2 m specimen containing twelve 12.7 mm strands in the target duct, at the nominal 80 mm embedment and 300 mm stirrup spacing; four loading–unloading rounds gave 40 acquired states. Estimating absolute tension failed to generalize across rounds for every regression model examined, the error exceeding the spread of the reference itself. A within-session difference representation gave a cross-validated coefficient of determination of 0.942 and a root-mean-square error of 169.0 kN, 13.5% of the 1252 kN full-scale reference. The binding constraint is therefore the signal representation rather than the regressor. Transfer across specimens, preservation of a reference between measurement epochs, and detection of small losses remain unverified.

Schlagwörter

Stichwörter der Autor:innen

Hall sensor arraychange detectionelasto-magnetic sensingexternal magnetizationmagnetic field measurementprestressed concretestructural health monitoringtendon tension

Autor:innen und Institutionen

  • AI Urban Disaster Prevention Research Center, Advanced Institute of Convergence Technology (AICT), Suwon 16229, Republic of Korea.
  • Shutagen Company Ltd., Ulsan 44481, Republic of Korea.
  • School of Civil, Architectural and Environmental System Engineering, Sungkyunkwan University, Suwon 16419, Republic of Korea.

ORCID-Profile: Seunghee Park

Förderung

  • Ministry of the Interior and Safety
  • National Research Foundation of Korea

Zitieren

APA

Park, S., Kim, J., Youm, M., & Park, S. (2026). External Magnetization-Based Elasto-Magnetic Sensing for Tension-Change Estimation in Prestressed Concrete Tendons. Sensors, 26(21), 7048. https://doi.org/10.3390/s26217048

Vancouver

Park S, Kim J, Youm M, Park S. External Magnetization-Based Elasto-Magnetic Sensing for Tension-Change Estimation in Prestressed Concrete Tendons. Sensors. 2026;26(21):7048. doi:10.3390/s26217048

BibTeX
@article{Park2026,
  author = {Park, Sehwan and Kim, Junkyeong and Youm, Minkyo and Park, Seunghee},
  title = {External Magnetization-Based Elasto-Magnetic Sensing for Tension-Change Estimation in Prestressed Concrete Tendons},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {7048},
  doi = {10.3390/s26217048}
}
Kostenlos starten →