A Semi-Automated Workflow for Quantitative Analysis of Right Ventricular Outflow Tract Geometry Based on 3D Point-Cloud Models
Sensors · 06.11.2026 · 26 (21) · 7037
DOI: 10.3390/s26217037 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.11.2026. Verfasst von Katarzyna Bobkowska und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland. Hauptthemen laut MEDLINE: Heart Ventricles, Imaging, Three-Dimensional. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Centre.
Abstract (Originalsprache)
The right ventricular outflow tract (RVOT) is an anatomically complex and spatially variable cardiac region that is difficult to characterise using isolated manual measurements. Although three-dimensional reconstruction techniques enable detailed visualisation of RVOT morphology, reproducible workflows for quantitative, level-based analysis of RVOT geometry remain limited. The aim of this methodological study was to develop and evaluate a semi-automated workflow for quantitative analysis of RVOT geometry based on 3D point-cloud models. This study represents a secondary methodological analysis of an existing anatomical dataset, introducing a new semi-automated workflow for systematic cross-section generation and quantitative descriptor extraction. Anatomical RVOT models were prepared from post-mortem material using silicone casting and digital photogrammetry. After point-cloud preparation, primary cross-sections were used to estimate a global directional reference. A mathematically defined inferior boundary plane and a predefined superior anatomical limit were then used to generate secondary cross-sections along the standardised RVOT segment. For each retained section, positional, ellipse-based, distance-based and area-based descriptors were extracted. The workflow was applied to 60 RVOT point-cloud models. After quality control, 661 secondary cross-sections were retained for analysis, with 5–16 sections per model and a mean of 11.02 ± 2.47 sections per model. Methodological validation included synthetic testing, comparison with manual measurements, and inter-observer assessment. Agreement with manual dimensions was high (ICC = 0.905–0.937), while inter-observer landmark variability was low (RMSE = 0.41 mm). An additional exploratory inter-observer assessment of three RVOT models yielded mean model-specific RMSE values of 12.97 mm2 for cross-sectional area and 0.54 mm for both ellipse axes. The proposed workflow provides a predefined geometric framework for quantitative description of RVOT geometry and should be regarded as a methodological proof of concept rather than a clinically validated measurement system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Narutowicza 11/12, 80-233 Gdańsk, Poland.
- Division of Clinical Anatomy, Medical University of Gdańsk, Dębinki 1, 80-211 Gdańsk, Poland.
ORCID-Profile: Katarzyna Bobkowska, Agata Kaczyńska-Miotk
Förderung
- National Science Centre
Zitieren
APA
Bobkowska, K., Kaczyńska-Miotk, A., & Kosiński, A. (2026). A Semi-Automated Workflow for Quantitative Analysis of Right Ventricular Outflow Tract Geometry Based on 3D Point-Cloud Models. Sensors, 26(21), 7037. https://doi.org/10.3390/s26217037
Vancouver
Bobkowska K, Kaczyńska-Miotk A, Kosiński A. A Semi-Automated Workflow for Quantitative Analysis of Right Ventricular Outflow Tract Geometry Based on 3D Point-Cloud Models. Sensors. 2026;26(21):7037. doi:10.3390/s26217037
BibTeX
@article{Bobkowska2026,
author = {Bobkowska, Katarzyna and Kaczyńska-Miotk, Agata and Kosiński, Adam},
title = {A Semi-Automated Workflow for Quantitative Analysis of Right Ventricular Outflow Tract Geometry Based on 3D Point-Cloud Models},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {7037},
doi = {10.3390/s26217037}
}
EUVIMED