EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Let Us Divide Twice: A New Design of Duplex Quantitative Lateral Flow Immunoassay

Nadezhda S Komova, Kseniya V Serebrennikova, Anatoly V Zherdev iD, Boris B Dzantiev iD

Sensors · 05.11.2026 · 26 (21) · 7012

DOI: 10.3390/s26217012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 05.11.2026. Verfasst von Nadezhda S Komova und 3 weiteren Autor:innen. Beteiligte Einrichtung: A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia. Hauptthemen laut MEDLINE: Hydrocortisone, Testosterone. Die Arbeit nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Simultaneous determination of salivary cortisol and testosterone levels could provide complementary information on the physiological status of the human body. However multiplex immunoassays are challenging because the two analytes occur at different concentration levels and the corresponding immunochemical reagents can interfere with one another. Here, we developed a duplex lateral flow immunoassay (LFIA) for simultaneous colorimetric determination of cortisol and testosterone. The assay was constructed on a single nitrocellulose membrane containing two spatially separated competitive immunoreaction zones. A distinctive feature of the immunoassay design was a selective interception zone that was located between the two test lines and functioned as an immunochemical sink. The optimized assay provided working ranges of 0.38–5.41 ng/mL for cortisol and 27–845 pg/mL for testosterone, with calculated detection limits of 0.18 ng/mL and 10.1 pg/mL, respectively. The analysis took 20 min and enabled the detection of both signals using a single test strip and colorimetric signal processing. Analysis of spiked artificial saliva samples yielded recoveries of 96.4–105.7%. The results demonstrate that spatial organization of immunochemical reactions may represent an alternative strategy for multiplexing LFIAs in cases where spectrally distinct labels are undesirable or when the analytical requirements of individual assays differ significantly.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrocortisoneTestosteroneImmunoassayHumansSalivaColorimetryCollodion

Stichwörter der Autor:innen

cortisollateral flow immunoassaymultiplex immunoassaysalivatestosterone

Substanzen

HydrocortisoneTestosteroneCollodion

Autor:innen und Institutionen

  • A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia.

ORCID-Profile: Anatoly V Zherdev, Boris B Dzantiev

Förderung

  • Russian Science Foundation

Zitieren

APA

Komova, N. S., Serebrennikova, K. V., Zherdev, A. V., & Dzantiev, B. B. (2026). Let Us Divide Twice: A New Design of Duplex Quantitative Lateral Flow Immunoassay. Sensors, 26(21), 7012. https://doi.org/10.3390/s26217012

Vancouver

Komova NS, Serebrennikova KV, Zherdev AV, Dzantiev BB. Let Us Divide Twice: A New Design of Duplex Quantitative Lateral Flow Immunoassay. Sensors. 2026;26(21):7012. doi:10.3390/s26217012

BibTeX
@article{Komova2026,
  author = {Komova, Nadezhda S and Serebrennikova, Kseniya V and Zherdev, Anatoly V and Dzantiev, Boris B},
  title = {Let Us Divide Twice: A New Design of Duplex Quantitative Lateral Flow Immunoassay},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {7012},
  doi = {10.3390/s26217012}
}
Kostenlos starten →