Two-Photodetector In-Phase and Quadrature Demodulation Interferometer Scheme Using Temporally Shifted Differential Signals
Sensors · 04.11.2026 · 26 (21) · 6967
DOI: 10.3390/s26216967 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 04.11.2026. Verfasst von June Gyu Park und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Astronomy, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Yonsei University, Yonsei University Research Fund.
Abstract (Originalsprache)
Four photodetectors, two in the balanced homodyne detector for in-phase (I) channel measurements and two in that for quadrature (Q) channel measurements, are needed for a conventional homodyne I/Q interferometer. Here, we present a new homodyne I/Q interferometer scheme for which two photodetectors, one for I-channel and the other for Q-channel measurements, are used for I/Q demodulation of the interference signal. The DC bias terms on the output signal from each photodetector are rejected by taking the difference between the signal and the temporally shifted signal. Then the induced phase on the interference signal can be measured by using the algorithm for I/Q phase demodulation. It will be shown that the sensitivity is limited by the corresponding photon noise. We will also show that in the vicinity of the turning points of a periodic modulation, where the phase difference may become smaller than the corresponding photon noise, or in the region where there is no measurable phase change the phase can be calculated through temporal averaging, which not only removes high-frequency noises but also increases the time delay for obtaining the difference signal.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Astronomy, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea.
- Department of Physics, Sogang University, Seoul 04107, Republic of Korea.
ORCID-Profile: June Gyu Park
Förderung
- National Research Foundation of Korea
- Yonsei University
- Yonsei University Research Fund
Zitieren
APA
Park, J. G., & Cho, K. (2026). Two-Photodetector In-Phase and Quadrature Demodulation Interferometer Scheme Using Temporally Shifted Differential Signals. Sensors, 26(21), 6967. https://doi.org/10.3390/s26216967
Vancouver
Park JG, Cho K. Two-Photodetector In-Phase and Quadrature Demodulation Interferometer Scheme Using Temporally Shifted Differential Signals. Sensors. 2026;26(21):6967. doi:10.3390/s26216967
BibTeX
@article{Park2026,
author = {Park, June Gyu and Cho, Kyuman},
title = {Two-Photodetector In-Phase and Quadrature Demodulation Interferometer Scheme Using Temporally Shifted Differential Signals},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6967},
doi = {10.3390/s26216967}
}