EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Three-Dimensional Partial Discharge Localization Method Based on Hybrid RSSI Fingerprint Maps and Minimal Deviation Model

Can Zhang, Xingzhou Yan iD, Lingen Luo iD, Gehao Sheng

Sensors · 04.11.2026 · 26 (21) · 6962

DOI: 10.3390/s26216962 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 04.11.2026. Verfasst von Can Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of High-Efficiency Special Cable Technology, School of Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, C…. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The UHF received signal strength indicator (RSSI) fingerprint map method was recently proposed to overcome the restrictions of the time delay algorithm widely used for partial discharge (PD) localization. However, existing studies focus on two-dimensional PD localization, while many situations require three-dimensional information. In addition, PD localization accuracy is highly dependent on the precision of prebuilt fingerprint maps, which remains challenging to achieve. Therefore, this paper proposes a hybrid three-dimensional PD localization method that combines RSSI fingerprint maps and a range-based algorithm. First, limited test points on several planes were selected to build RSSI fingerprint maps. Then, single-plane smooth interpolation was employed for each plane to obtain smooth three-dimensional fingerprint maps. Here, the limited test points compensate for the non-line-of-sight (NLOS) effect, while the interpolation method reduced the workload required to build the fingerprint map. Thirdly, enhanced four-dimensional fingerprint maps were established based on the Kriging method. Finally, a minimal deviation model was proposed to locate the position of the PD source by analyzing the relative ratio of the RSSI values across different sensors. Laboratory validation shows that the average error of the proposed method is 0.69 m, which demonstrates its accuracy and practical application value of the proposed method.

Schlagwörter

Stichwörter der Autor:innen

KrigingRSSIfingerprintpartial dischargethree-dimensional localization

Autor:innen und Institutionen

  • State Key Laboratory of High-Efficiency Special Cable Technology, School of Electrical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.

ORCID-Profile: Xingzhou Yan, Lingen Luo

Zitieren

APA

Zhang, C., Yan, X., Luo, L., & Sheng, G. (2026). Three-Dimensional Partial Discharge Localization Method Based on Hybrid RSSI Fingerprint Maps and Minimal Deviation Model. Sensors, 26(21), 6962. https://doi.org/10.3390/s26216962

Vancouver

Zhang C, Yan X, Luo L, Sheng G. Three-Dimensional Partial Discharge Localization Method Based on Hybrid RSSI Fingerprint Maps and Minimal Deviation Model. Sensors. 2026;26(21):6962. doi:10.3390/s26216962

BibTeX
@article{Zhang2026,
  author = {Zhang, Can and Yan, Xingzhou and Luo, Lingen and Sheng, Gehao},
  title = {Three-Dimensional Partial Discharge Localization Method Based on Hybrid RSSI Fingerprint Maps and Minimal Deviation Model},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {6962},
  doi = {10.3390/s26216962}
}