Silver Thickness Optimization for Sensitivity Enhancement in a Surface Plasmon Resonance Biosensor for Multi-Cancer Detection
Sensors · 03.11.2026 · 26 (21) · 6954
DOI: 10.3390/s26216954 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 03.11.2026. Verfasst von Rajeev Kumar und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Communication Engineering, Graphic Era (Deemed to Be University), Dehradun 248001, Uttarakhand, India. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Silver, Biosensing Techniques, Neoplasms. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This work proposes a highly sensitive Surface Plasmon Resonance (SPR) biosensor for label-free refractive index (RI) and biological sensing applications based on a BK7 prism-coupled bimetal (Ag/Au) and Tantalum Diselenide (TaSe2) hybrid structure. The transfer matrix method (TMM) is used to examine the sensing performance of the suggested structure while accounting for the effects of various biological sensing media (SM) and plasmonic layer thickness. To attain optimal plasmonic coupling, the impact of Ag layer thickness on sensitivity and minimum reflectance (Rmin) is methodically examined. For the long RI range of 1.35–1.40, the maximum sensitivity is 206.32°/RIU at the Rmin value. Depending on the sensing layer, the Ag thickness ranges from 39 to 42 nm, offering better resonance properties for various cancer detection. Basal, HeLa, Jurkat, PC12, MM-231 and MCF-7 have remarkable Rmin values and the highest sensitivity of 260.49°/RIU, 280.13°/RIU, 290.24°/RIU 260.49°/RIU, 280.13°/RIU and 290.24°/RIU with an optimized Ag thickness of 42–39 nm among the biological layers under investigation, respectively. Moreover, the penetration depth (PD) of 192.94 nm and 181.5 nm is attained at RIs of SM 1.35 and 1.40. The suggested SPR biosensor is a promising platform for biosensing, disease diagnosis, and real-time monitoring applications because of its exceptional sensitivity, low resonance reflectance, and improved detection capability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electronics and Communication Engineering, Graphic Era (Deemed to Be University), Dehradun 248001, Uttarakhand, India.
- McKesson Corporation, 32559 Lake Bridgeport St, Fremont, CA 94555, USA.
- Department of Electronics and Communication Engineering, Sikkim Manipal Institute of Technology, Sikkim Manipal University, Majitar 737136, Sikkim, India.
- Institute of Information Science and Technologies, National Research Council, 56124 Pisa, Italy.
- Symbiosis Institute of Technology, Pune Campus, Symbiosis International (Deemed University), Pune 412115, India.
ORCID-Profile: Rajeev Kumar, Biswajit Brahma, Jitendra Singh Tamang, Paolo Barsocchi, Akash Kumar Bhoi
Zitieren
APA
Kumar, R., Brahma, B., Tamang, J. S., Barsocchi, P., & Bhoi, A. K. (2026). Silver Thickness Optimization for Sensitivity Enhancement in a Surface Plasmon Resonance Biosensor for Multi-Cancer Detection. Sensors, 26(21), 6954. https://doi.org/10.3390/s26216954
Vancouver
Kumar R, Brahma B, Tamang JS, Barsocchi P, Bhoi AK. Silver Thickness Optimization for Sensitivity Enhancement in a Surface Plasmon Resonance Biosensor for Multi-Cancer Detection. Sensors. 2026;26(21):6954. doi:10.3390/s26216954
BibTeX
@article{Kumar2026,
author = {Kumar, Rajeev and Brahma, Biswajit and Tamang, Jitendra Singh and Barsocchi, Paolo and Bhoi, Akash Kumar},
title = {Silver Thickness Optimization for Sensitivity Enhancement in a Surface Plasmon Resonance Biosensor for Multi-Cancer Detection},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6954},
doi = {10.3390/s26216954}
}
EUVIMED