EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity of Functional Performance Outcomes and Gait Metrics Measured by Smartphone Application in Patients with Chronic Stroke

Gabriela Rozanski iD, Jessica Polizzi, Aidan Rogers iD, Megha Amin, Wilber Parada Iraheta, Karolina Roszkowski, Jenna Tosto-Mancuso iD, David Putrino

Sensors · 03.11.2026 · 26 (21) · 6947

DOI: 10.3390/s26216947 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 03.11.2026. Verfasst von Gabriela Rozanski und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA. Hauptthemen laut MEDLINE: Smartphone, Stroke, Mobile Applications, Gait. Die Arbeit nennt 84 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Celloscope Inc, Celloscope Inc..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate assessment of impaired functional mobility is crucial to track recovery and guide interventions after stroke. Conventionally, physical therapists administer semi-objective rating scales or manually record performance on various tests. Technological developments, particularly automated algorithms that use motion data from inertial sensors, offer a promising solution for more efficient and objective evaluations. This cross-sectional analysis examined the agreement between therapist-recorded measures and a smartphone application (OneStep) for the Chair Stand Test (CST), Timed Up and Go (TUG), and the Six-Minute Walk Test (6MWT) in 42 participants with chronic stroke (mean age 54 years, 50% male). Analysis was measured via a two-way random-effect intraclass correlation coefficient analysis ICC(2,1) (absolute agreement) and Bland–Altman limits of agreement. ICC(2,1) was 0.989 [0.980, 0.994] for the CST, 0.995 [0.985, 0.998] for the TUG, and 0.921 [0.776, 0.967] for the 6MWT. Mean differences (therapist–app score) were −0.08 repetitions (CST), −1.03 s (TUG). and −69 feet (6MWT). Within-session repeatability was not detectably different between the app and therapist for the CST (SEM ratio app/therapist 0.91 [0.76, 1.05]) or the TUG (1.36 [0.92, 2.13]); the TUG estimates are imprecise and do not establish equivalence. The 6MWT was not considered in within-session repeatability as multiple tests were not completed due to patient fatigue. App failure rates were relatively low for the CST (2/80), TUG (3/76), and 6MWT (5/36). Correlations with patient-reported outcomes, clinician-rated outcomes, and gait metrics were exploratory (89 of 115 significant after false discovery rate correction). The results suggest close agreement for the CST, a small systematic difference for the TUG, and larger differences for the 6MWT. Future research should address the longitudinal predictive utility and broader implementation throughout the health care system of mobile applications like OneStep.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneStrokeMobile ApplicationsGaitHumansMiddle AgedMaleFemaleStroke RehabilitationChronic DiseaseCross-Sectional StudiesAged

Stichwörter der Autor:innen

functional mobilitygait analysispatient-reported outcomesperformance-based measuressmartphonestrokevalidity

Autor:innen und Institutionen

  • Department of Rehabilitation and Human Performance, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.

ORCID-Profile: Gabriela Rozanski, Aidan Rogers, Jenna Tosto-Mancuso

Förderung

  • Celloscope Inc
  • Celloscope Inc.

Zitieren

APA

Rozanski, G., Polizzi, J., Rogers, A., Amin, M., Parada Iraheta, W., Roszkowski, K., Tosto-Mancuso, J., & Putrino, D. (2026). Validity of Functional Performance Outcomes and Gait Metrics Measured by Smartphone Application in Patients with Chronic Stroke. Sensors, 26(21), 6947. https://doi.org/10.3390/s26216947

Vancouver

Rozanski G, Polizzi J, Rogers A, Amin M, Parada Iraheta W, Roszkowski K, et al. Validity of Functional Performance Outcomes and Gait Metrics Measured by Smartphone Application in Patients with Chronic Stroke. Sensors. 2026;26(21):6947. doi:10.3390/s26216947

BibTeX
@article{Rozanski2026,
  author = {Rozanski, Gabriela and Polizzi, Jessica and Rogers, Aidan and Amin, Megha and Parada Iraheta, Wilber and Roszkowski, Karolina and Tosto-Mancuso, Jenna and Putrino, David},
  title = {Validity of Functional Performance Outcomes and Gait Metrics Measured by Smartphone Application in Patients with Chronic Stroke},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {6947},
  doi = {10.3390/s26216947}
}
Kostenlos starten →