Electrochemical Sensing of Estradiol Using an Fe3O4/fMWCNT-Modified Carbon Paste Electrode
Sensors · 31.10.2026 · 26 (21) · 6917
DOI: 10.3390/s26216917 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 31.10.2026. Verfasst von Ana Đurović und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Technology Novi Sad, University of Novi Sad, Bul. cara Lazara 1, 21102 Novi Sad, Serbia. Hauptthemen laut MEDLINE: Estradiol, Nanotubes, Carbon, Electrochemical Techniques. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, Technological Development, and Innovation of the Republic of Serbia, Ministry of Science, Technological Development and Innovation of the Republic of Serbia.
Abstract (Originalsprache)
A sensitive and reproducible electroanalytical method was developed for the selective determination of estrogen hormone estradiol (EST) using a carbon paste electrode (CPE) modified with Fe3O4-functionalized multi-walled carbon nanotubes (Fe3O4/fMWCNTs-CPE). The Fe3O4/fMWCNT composite was synthesized via wet impregnation and characterized by field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction, while the sensor’s electrochemical and interfacial properties were assessed using cyclic voltammetry and electrochemical impedance spectroscopy. Electrochemical studies revealed an irreversible oxidation peak for EST, and square-wave voltammetry was optimized for its determination in 0.1 mol/L phosphate buffer (pH 5.0). Under optimal conditions, the sensor exhibited a linear dynamic range (up to 20 µM) with a detection limit of 21.5 nM, indicating high sensitivity. Moreover, it showed good selectivity in the presence of common interfering substances. The method was successfully applied for EST determination in one urine sample, one water sample, and one pharmaceutical tablet sample, achieving high recovery values (98.53–101.79%), with RSD values below 2.40%, requiring only sample dilution without additional pretreatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Technology Novi Sad, University of Novi Sad, Bul. cara Lazara 1, 21102 Novi Sad, Serbia.
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemědělská 1, 613 00 Brno, Czech Republic.
ORCID-Profile: Ana Đurović, Zorica Stojanović, Sanja Panić, Marija Milanović, Snežana Kravić, Lukáš Richtera
Förderung
- Ministry of Science, Technological Development, and Innovation of the Republic of Serbia
- Ministry of Science, Technological Development and Innovation of the Republic of Serbia
Zitieren
APA
Đurović, A., Stojanović, Z., Panić, S., Milanović, M., Kravić, S., & Richtera, L. (2026). Electrochemical Sensing of Estradiol Using an Fe3O4/fMWCNT-Modified Carbon Paste Electrode. Sensors, 26(21), 6917. https://doi.org/10.3390/s26216917
Vancouver
Đurović A, Stojanović Z, Panić S, Milanović M, Kravić S, Richtera L. Electrochemical Sensing of Estradiol Using an Fe3O4/fMWCNT-Modified Carbon Paste Electrode. Sensors. 2026;26(21):6917. doi:10.3390/s26216917
BibTeX
@article{urovi2026,
author = {Đurović, Ana and Stojanović, Zorica and Panić, Sanja and Milanović, Marija and Kravić, Snežana and Richtera, Lukáš},
title = {Electrochemical Sensing of Estradiol Using an Fe3O4/fMWCNT-Modified Carbon Paste Electrode},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6917},
doi = {10.3390/s26216917}
}
EUVIMED