EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Graphene-Integrated Dual-Channel q-BIC Metasurface for Actively Tunable and Self-Calibrated Mid-Infrared SO2 Sensing

Zhengshan Xu iD, Dashuai Xu, Yang He, Tonggang Zhao

Sensors · 30.10.2026 · 26 (21) · 6889

DOI: 10.3390/s26216889 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 30.10.2026. Verfasst von Zhengshan Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Beijing Key Laboratory of Space-Ground Interconnection and Convergence, Beijing University of Posts and Telecommunications, Beijing 100876, China. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mid-infrared gas sensors exploit molecular vibrational absorption but remain vulnerable to source fluctuation, background refractive-index drift, and fabrication-induced spectral mismatch. We numerically propose a graphene-integrated dual-channel quasi-bound-state-in-the-continuum (q-BIC) metasurface for SO2 detection near 8.6 μm. Symmetry breaking in square–hollow silicon nanopillars produces two leaky resonances with distinct modal origins, denoted P1 and P2. P1 is aligned with the SO2 absorption band and serves as the sensing channel, whereas P2 provides an off-band reference. Graphene gating enables post-fabrication spectral alignment. At the graphene Fermi level EF=0.516 eV, the refractive-index sensitivities of P1 and P2 are 2280 nm RIU−1 and 564.6 nm RIU−1, respectively. Under 1% source fluctuation, the ideal common-mode model predicts an approximately 17 dB signal-to-noise ratio (SNR) improvement over single-channel detection. The field-overlap model gives an uncalibrated limit of detection (LOD) of 46.1 ppm and a conditional value of 6.5 ppm under an illustrative rescaled noise budget with negligible additional calibration errors. A value of 4.61 ppm requires the total corrected equivalent absorption noise to reach 1.0×10−7. These assumption-dependent estimates are not experimentally measured detection limits. The proposed architecture provides a compact platform for active spectral alignment and dual-channel self-calibration in mid-infrared gas sensing.

Schlagwörter

Stichwörter der Autor:innen

SO2 detectiongraphene tuningmid-infrared gas sensingq-BIC metasurfaceratiometric self-calibrationrefractive-index drift

Autor:innen und Institutionen

  • Beijing Key Laboratory of Space-Ground Interconnection and Convergence, Beijing University of Posts and Telecommunications, Beijing 100876, China.
  • School of Electronic Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, China.

ORCID-Profile: Zhengshan Xu

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Xu, Z., Xu, D., He, Y., & Zhao, T. (2026). Graphene-Integrated Dual-Channel q-BIC Metasurface for Actively Tunable and Self-Calibrated Mid-Infrared SO2 Sensing. Sensors, 26(21), 6889. https://doi.org/10.3390/s26216889

Vancouver

Xu Z, Xu D, He Y, Zhao T. Graphene-Integrated Dual-Channel q-BIC Metasurface for Actively Tunable and Self-Calibrated Mid-Infrared SO2 Sensing. Sensors. 2026;26(21):6889. doi:10.3390/s26216889

BibTeX
@article{Xu2026,
  author = {Xu, Zhengshan and Xu, Dashuai and He, Yang and Zhao, Tonggang},
  title = {Graphene-Integrated Dual-Channel q-BIC Metasurface for Actively Tunable and Self-Calibrated Mid-Infrared SO2 Sensing},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {6889},
  doi = {10.3390/s26216889}
}
Kostenlos starten →