EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+

Manon W H Peeters iD, Bo A C Dirks iD, Sjoerd Kesteloo iD, Bart van Boxtel iD, Petra Heck iD, Gerard Schouten

Sensors · 27.10.2026 · 26 (21) · 6795

DOI: 10.3390/s26216795 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 27.10.2026. Verfasst von Manon W H Peeters und 5 weiteren Autor:innen. Beteiligte Einrichtung: School for Allied Health Professions, Fontys University of Applied Sciences, Postbus 347, 5600 AH Eindhoven, The Netherlands. Hauptthemen laut MEDLINE: Galvanic Skin Response, Wrist, Wearable Electronic Devices, Stress, Psychological. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Regieorgaan SIA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable electrodermal activity (EDA) monitoring enables assessment of stress-related physiological changes in daily life, but new devices require validation. This study evaluated the newly introduced EmbracePlus against the Shimmer3 GSR+, used as a research-grade wrist-based comparator. Healthy volunteers (n = 53; n = 41 valid paired recordings) completed breathing exercises, a Stroop task, and a virtual reality (VR) height stressor while wearing both devices simultaneously on the non-dominant wrist. Agreement was assessed at signal, parameter, and event levels for mean phasic activity, skin conductance level (SCL), summed skin conductance response (SCR) amplitude/min, and SCR count/min. Mean signal-level cross-correlation was r = 0.30. At the parameter level, only 44% of SCL, 24% of SCR amplitude/min, and 5% of SCR count/min differences fell within a priori acceptable boundaries, and regression analyses indicated proportional bias for mean phasic activity, summed SCR amplitude/min and SCR count/min. At the event level, Shimmer3 detected increases across all four EDA metrics during both stress tasks (all p < 0.001). EmbracePlus showed increases across all four metrics during VR (all p < 0.001), whereas during Stroop only mean phasic activity (p = 0.001) and SCL (p < 0.001) increased. EmbracePlus and Shimmer3 are therefore not interchangeable for absolute EDA assessment, and EmbracePlus validity depends on stressor intensity and metric selection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Galvanic Skin ResponseWristWearable Electronic DevicesStress, PsychologicalStress, PhysiologicalHumansFemaleAdultMaleYoung AdultMonitoring, Physiologic

Stichwörter der Autor:innen

EmbracePlusShimmer3 GSR+electrodermal activitystresswearable validation

Autor:innen und Institutionen

  • School for Allied Health Professions, Fontys University of Applied Sciences, Postbus 347, 5600 AH Eindhoven, The Netherlands.
  • Human-Technology Interaction Group, Faculty Industrial Engineering & Innovation Sciences, Eindhoven University of Technology, Postbus 513, 5600 MB Eindhoven, The Netherlands.
  • School for Information & Communication Technology, Fontys University of Applied Sciences, Postbus 347, 5600 AH Eindhoven, The Netherlands.

ORCID-Profile: Manon W H Peeters, Bo A C Dirks, Sjoerd Kesteloo, Bart van Boxtel, Petra Heck

Förderung

  • Regieorgaan SIA

Zitieren

APA

Peeters, M. W. H., Dirks, B. A. C., Kesteloo, S., van Boxtel, B., Heck, P., & Schouten, G. (2026). Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+. Sensors, 26(21), 6795. https://doi.org/10.3390/s26216795

Vancouver

Peeters MWH, Dirks BAC, Kesteloo S, van Boxtel B, Heck P, Schouten G. Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+. Sensors. 2026;26(21):6795. doi:10.3390/s26216795

BibTeX
@article{Peeters2026,
  author = {Peeters, Manon W H and Dirks, Bo A C and Kesteloo, Sjoerd and van Boxtel, Bart and Heck, Petra and Schouten, Gerard},
  title = {Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {21},
  pages = {6795},
  doi = {10.3390/s26216795}
}
Kostenlos starten →