Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+
Sensors · 27.10.2026 · 26 (21) · 6795
DOI: 10.3390/s26216795 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.10.2026. Verfasst von Manon W H Peeters und 5 weiteren Autor:innen. Beteiligte Einrichtung: School for Allied Health Professions, Fontys University of Applied Sciences, Postbus 347, 5600 AH Eindhoven, The Netherlands. Hauptthemen laut MEDLINE: Galvanic Skin Response, Wrist, Wearable Electronic Devices, Stress, Psychological. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Regieorgaan SIA.
Abstract (Originalsprache)
Wearable electrodermal activity (EDA) monitoring enables assessment of stress-related physiological changes in daily life, but new devices require validation. This study evaluated the newly introduced EmbracePlus against the Shimmer3 GSR+, used as a research-grade wrist-based comparator. Healthy volunteers (n = 53; n = 41 valid paired recordings) completed breathing exercises, a Stroop task, and a virtual reality (VR) height stressor while wearing both devices simultaneously on the non-dominant wrist. Agreement was assessed at signal, parameter, and event levels for mean phasic activity, skin conductance level (SCL), summed skin conductance response (SCR) amplitude/min, and SCR count/min. Mean signal-level cross-correlation was r = 0.30. At the parameter level, only 44% of SCL, 24% of SCR amplitude/min, and 5% of SCR count/min differences fell within a priori acceptable boundaries, and regression analyses indicated proportional bias for mean phasic activity, summed SCR amplitude/min and SCR count/min. At the event level, Shimmer3 detected increases across all four EDA metrics during both stress tasks (all p < 0.001). EmbracePlus showed increases across all four metrics during VR (all p < 0.001), whereas during Stroop only mean phasic activity (p = 0.001) and SCL (p < 0.001) increased. EmbracePlus and Shimmer3 are therefore not interchangeable for absolute EDA assessment, and EmbracePlus validity depends on stressor intensity and metric selection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School for Allied Health Professions, Fontys University of Applied Sciences, Postbus 347, 5600 AH Eindhoven, The Netherlands.
- Human-Technology Interaction Group, Faculty Industrial Engineering & Innovation Sciences, Eindhoven University of Technology, Postbus 513, 5600 MB Eindhoven, The Netherlands.
- School for Information & Communication Technology, Fontys University of Applied Sciences, Postbus 347, 5600 AH Eindhoven, The Netherlands.
ORCID-Profile: Manon W H Peeters, Bo A C Dirks, Sjoerd Kesteloo, Bart van Boxtel, Petra Heck
Förderung
- Regieorgaan SIA
Zitieren
APA
Peeters, M. W. H., Dirks, B. A. C., Kesteloo, S., van Boxtel, B., Heck, P., & Schouten, G. (2026). Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+. Sensors, 26(21), 6795. https://doi.org/10.3390/s26216795
Vancouver
Peeters MWH, Dirks BAC, Kesteloo S, van Boxtel B, Heck P, Schouten G. Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+. Sensors. 2026;26(21):6795. doi:10.3390/s26216795
BibTeX
@article{Peeters2026,
author = {Peeters, Manon W H and Dirks, Bo A C and Kesteloo, Sjoerd and van Boxtel, Bart and Heck, Petra and Schouten, Gerard},
title = {Validity Assessment of Wrist-Worn Electrodermal Activity Measurement During Relaxation and Acute Stressor Tasks: Comparing the EmbracePlus and Shimmer3 GSR+},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6795},
doi = {10.3390/s26216795}
}