An ESP32-S3 Multimodal Wearable Sensor Platform with Embedded XGBoost for Focal-to-Bilateral Tonic–Clonic Seizure Detection and IoT Alerting
Sensors · 23.10.2026 · 26 (21) · 6710
DOI: 10.3390/s26216710 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 23.10.2026. Verfasst von Mohamed Ali Torad und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Communication Engineering, Higher Technological Institute (HTI), 10th of Ramadan City 44634, Egypt. Hauptthemen laut MEDLINE: Seizures, Wearable Electronic Devices, Internet of Things. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Princess Nourah bint Abdulrahman University.
Abstract (Originalsprache)
Wearable seizure-detection systems can provide objective event monitoring and rapid caregiver alerting without continuous bedside observation. This study presents a resource-constrained multimodal wearable sensor platform for focal-to-bilateral tonic–clonic seizure (FBTCS) detection using edge artificial intelligence and Internet of Things (IoT) communication. The prototype integrates an ESP32-S3 microcontroller, an analog electromyography (EMG) channel, an MPU6050 inertial sensor, MAX30102 photoplethysmography, GPS, a TFT display, local vibration/buzzer outputs, and Blynk cloud telemetry. The seizure–decision path uses synchronized EMG and acceleration acquired at 100 Hz in non-overlapping 10 s windows. EMG and acceleration are resampled for compatibility with the reference feature pipeline, 13 statistical features are extracted from each modality (26 total), and an 85-tree XGBoost model is executed locally. A probability threshold of 0.85 is combined with temporal smoothing, consecutive-window confirmation, and a 60 s refractory interval. Software verification showed maximum absolute probability differences of approximately 1.19 × 10−7 for random feature-vector tests and 1.49 × 10−8 for end-to-end recorded windows relative to the Python reference. Within the reported validation record covering 2643.69 h and 18 record-labeled FBTCS events, 12 events were detected (12/18; 67% sensitivity). Precision was approximately 26%, F1-score approximately 38%, the reported false-alarm rate was 0.31 per 24 h, and median detection latency was 61.5 s. Approximately 34 false alarms are estimated from the reported false-alarm rate and evaluation duration; this is an estimated count rather than a percentage or directly observed count. Hardware, local alarm, display, GPS, and cloud communication functions passed functional integration tests. The small event count, uncertain label provenance, low precision, and long latency mean that these data support an engineering proof-of-concept only and do not establish clinical applicability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics and Communication Engineering, Higher Technological Institute (HTI), 10th of Ramadan City 44634, Egypt.
- Department of Physical Therapy and Health Rehabilitation, Jouf University, Sakaka 72341, Saudi Arabia.
- Department of Basic Sciences, Faculty of Physical Therapy, Kafrelsheikh University, Kafrelsheikh 33516, Egypt.
- Department of Rehabilitation Sciences, College of Health and Rehabilitation Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.
- Neurocognitive Research Centre, Nyírő Gyula National Institute of Psychiatry and Addictology, 1085 Budapest, Hungary.
- Department of Anatomy, Histology and Embryology, Semmelweis University, 1085 Budapest, Hungary.
ORCID-Profile: Mohamed Ali Torad, Ahmed Ali Mohamed Torad, Mona Mohamed Taha, Mohamed Abdelaziz Emam
Förderung
- Princess Nourah bint Abdulrahman University
Zitieren
APA
Torad, M. A., Thabet, M. H., Taha, M. Y., Torad, A. A. M., Taha, M. M., Horváth, A. A., & Emam, M. A. (2026). An ESP32-S3 Multimodal Wearable Sensor Platform with Embedded XGBoost for Focal-to-Bilateral Tonic–Clonic Seizure Detection and IoT Alerting. Sensors, 26(21), 6710. https://doi.org/10.3390/s26216710
Vancouver
Torad MA, Thabet MH, Taha MY, Torad AAM, Taha MM, Horváth AA, et al. An ESP32-S3 Multimodal Wearable Sensor Platform with Embedded XGBoost for Focal-to-Bilateral Tonic–Clonic Seizure Detection and IoT Alerting. Sensors. 2026;26(21):6710. doi:10.3390/s26216710
BibTeX
@article{Torad2026,
author = {Torad, Mohamed Ali and Thabet, Mina Hany and Taha, Mohammed Youssef and Torad, Ahmed Ali Mohamed and Taha, Mona Mohamed and Horváth, András Attila and Emam, Mohamed Abdelaziz},
title = {An ESP32-S3 Multimodal Wearable Sensor Platform with Embedded XGBoost for Focal-to-Bilateral Tonic–Clonic Seizure Detection and IoT Alerting},
journal = {Sensors},
year = {2026},
volume = {26},
number = {21},
pages = {6710},
doi = {10.3390/s26216710}
}
EUVIMED